Description

 

Combination Refrigerated Drinking Fountain (Cooler) with bottle filling station delivers chilled, clean potable drinking water. Two-level water cooler 

houses the refrigeration and delivers a steady stream of water for direct drinking at the press of the front and sidebars.

Ratings

     •     Electrical: 230Vac, 50Hz, (See Nameplate for Amperage), 1 phase.

     •     Ambient Air Temperature: 50-100.4 °F (10-38 °C).

     •     Water Pressure: 20-100 psig (0.14-0.69 MPa).

     •     Maximum Water Temperature: 90 °F (32 °C).

     •     Refrigerant: HFC-R134a

     •     Ingress Protection: IP2x

     •     For Indoor Commercial Use only.

     •     Water Inlet: 3/8” (9.5mm) O.D. unplated copper tube.

     •     Waste Water Outlet: 1-1/2” (38.1mm) O.D. tube

DANGER

 

– Indicates death or serious injury will result if proper precautions are not taken.

WARNING

 – Indicates death, serious injury or property damage can result if proper precautions are not taken.

CAUTION

 – Indicates some injury or property damage may result if proper precautions are not taken.

Definitions

Authorized Service Personnel

 – Factory trained personnel or personnel having working knowledge of electrical, plumbing and 

machine (appliance) maintenance procedures.

Safety

DANGER

     •     Please read these instructions completely before starting the installation or performing any service. Failure to follow the instructions and

           safety precautions in this manual can result in serious injury or death.

     •     After installation, keep these instructions in a safe location for future reference.

     •     Electric supply must be identical in voltage, cycle, and phase to that specified on nameplate.

     •     Electrical supply must have Ground Fault Circuit Interrupter (GFCI) protection. 

     •     A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules. This is

           to allow electrical disconnection of the unit from electrical supply after installation. 

WARNING

     •     For use with clean, clear potable drinking water only. Do not use with water that is microbiologically unsafe or of unknown quality

           without adequate disinfection before the system.

     •     Installation and connection to water and electrical mains must be in compliance with local and national laws. 

     •     All Installation and Service work must be performed by an authorized service personnel. 

CAUTION

     •     This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental

           capabilities or lack of experience and knowledge if they have been given supervision or instructions concerning use of the appliance

           in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall

           not be made by children without supervision.

     •     To prevent a metallic taste or increased metal content in the water due to an electrolysis process caused by electrical feedback from

           the grounding of electrical equipment to water supply and water waste mains, connect to these mains using non-conductive

           materials. The provided solenoid valve regulator assembly meets this requirement.

Alternate Mounting Configurations

Configuration as Shipped

Installation / Care / Use Manual

Original Instructions

Models: LZSTL8WSL2K, LZSTL8WSS2K, LZSTL8WSVRL2K, 

LZSTL8WSVRS2K

Summary of Contents for LZSTL8WSL2K

Page 1: ...in voltage cycle and phase to that specified on nameplate Electrical supply must have Ground Fault Circuit Interrupter GFCI protection A means for disconnecting electrical supply to the unit must be...

Page 2: ...rap Remove the slip nut and gasket from the waste trap and install them on the cooler waste line making sure that the end of the waste line fits into the waste trap Assemble the slip nut and gasket to...

Page 3: ...to ensure proper clearance and free fan action 3 Connect plug end of International Power Cord Set sold separately into electrical outlet WARNING Exposed electrically energized components Use extreme c...

Page 4: ...4 11mm X 19mm OBROUND HOLES 6 15 381mm 2 7 8 73mm 2 51mm 51 9 16 1310mm 28 13 16 732mm 19 483mm 17 7 16 443mm 13 15 16 354mm 24 1 2 622mm 34 5 16 872mm 2 51mm 22 15 16 583mm 19 7 16 494mm 7 178mm 7 1...

Page 5: ...4 11mm X 19mm OBROUND HOLES 6 15 381mm 2 7 8 73mm 2 51mm 51 9 16 1310mm 28 13 16 732mm 19 483mm 17 7 16 443mm 13 15 16 354mm 24 1 2 622mm 34 5 16 872mm 2 51mm 22 15 16 583mm 19 7 16 494mm 7 178mm 7 17...

Page 6: ...ventilation can cause no cold water and compressor cycling on the compressor overload protector 5 Water Flow Confirm proper water flow If water flow is slow inspect filter or inline strainer for restr...

Page 7: ...be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG o...

Page 8: ...ED IN POSITION PUSH IN COLLET TO RELEASE TUBE PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE A B C Fig 12 DESCRIPTION 1 2 3 ITEM NO PART NO 51300C 98926C 0000000746 Filter Assy 3000 Gal K...

Page 9: ...15 LZSTL8WS_2D 19 8A 1 2A 12 19 12 19 4 28 19 16 2B 12 3 6 19 18 19 8B 21 1 15 16 13 5 3 6 5 17 20 7 26 31 22 32 23 Stream Height Adjustment Stream Height Adjustment Unit is pictured without bottle f...

Page 10: ...Side Push Drier Kit Drain Replacement EZTL8 Brkt Tube Ftg Clamp Kit Drain Replacement EZTLD BF Brkt Tube Ftg Clamp Kit Replacement Cap Screen O Ring Kit Solenoid Valve Regulator Assy Kit Flexi Bubble...

Page 11: ...basin assembly off the cooler frame 2 Disconnect two 2 black wires coming from the shroud assembly Black wire that connects from shroud assembly to solenoid valve Black wire that connects to white wi...

Page 12: ...n front of the frame tipped up as shown in picture to the right 2 Connect water line to solenoid valve Reference Figure 10 for operation of quick connect fittings 3 Connect two 2 black wires coming fr...

Page 13: ...piece to wrapper with 2 screws provided 3 Re install wrapper with 4 screws 4 Dispose of unused cover plate Right Hand Wrapper Low Side 1 Remove existing wrapper by removing the 4 screws from bottom 2...

Page 14: ...ev C 11 15 PLUMBING DIAGRAMS VERSATILE BI LEVEL Barb capped when not used Barb capped when not used Barb capped when not used Barb capped when not used Bottle Filler Drain Bottle Filler Drain Bottle F...

Page 15: ...Refrig unit L H Non Refrig unit Bubbler Bubbler Evaporator 3 8 Water Inlet Tee 3 8 Water Line from Bottle Filling Unit H Filter Assembly 1 4 Union Solenoid Valve Solenoid Valve PLUMBING DIAGRAMS FOR E...

Reviews: