Important: after installation is 

completed, turn on hot and cold water 
supplies. Check for leaks. Pull the 
hose assembly out of the spout and 
remove the spray head by unscrewing 
it from the hose counterclockwise. Be 
sure to hold the end of the hose down 
into the sink and turn the faucet on to 
the warm position where it mixes hot 
and cold water. Flush water lines for 
one minute. Check for leaks. 
Re-tighten any connections if 
necessary, but do not overtighten. 
Reinstall spray head by hand 
tightening it back onto the spray hose. 

Make connections to water lines with 
3/8" female compression supply 
hoses (1). 
If additional hose length is needed, 
attach included 1/2" MIP thread 
adaptors (2) to supply hoses (1). Use 
1/2" I.P.S. faucet connections (3) or 
use coupling nuts (5) with 3/8" 
O.D.ball-nose riser (4) to make 
connections to water lines. Use 

wrenches to tighten connections. Do 

not overtighten.

Screw quick connector to the free end of 
pull-down hose. Align male fitting (1) and 
tabs (2) on quick connector. Push quick 
connector housing firmly upward and 
snap onto receiving male fitting. Pull down 
moderately to ensure connection has 
been made. After connecting the hose, 
attach weights (3) to hose at bottom of 
loop to prevent hose from twisting and 
return hose to proper position.

Retract pull-down hose (1) up through 

faucet body, until the pull-down hose 
fitting is flush with the bottom of shank 

(2). Do not pull hose fitting past the 
shank. Insert faucet body through the 
hole in sink. From underneath sink, 
install plastic washer (3), metal washer 
(4) and nut (5) onto the mounting shank. 
Do not overtighten. 
Note: Do not feed the pull-down hose (1) 
back down through the spout until step 3.

Shut off water supplies. 
Before installation, remove quick 
connect assembly (1) from the free end 
of pull-down hose.

WARNING: Please carefully read and properly follow the instructions for installation found in this manual.

STEPS:

1

1

2

3
4
5

1

2

3

Ø 1 3/8" (Ø35mm)

4

3

5

2

1

Summary of Contents for LKHA4032

Page 1: ... INSTALLATION OWNER S MANUAL OPTIONAL 2 2GPM FLOW REGULATOR You choose the flow rate This faucet ships with an eco friendly 1 5GPM flow regulator installed If you desire higher flow rate a 2 2GPM flow regulator has also been included in the box Switching the flow regulator is simple See the Flow Regulator Replacement section for details Important ...

Page 2: ...Do not overtighten Screw quick connector to the free end of pull down hose Align male fitting 1 and tabs 2 on quick connector Push quick connector housing firmly upward and snap onto receiving male fitting Pull down moderately to ensure connection has been made After connecting the hose attach weights 3 to hose at bottom of loop to prevent hose from twisting and return hose to proper position Retr...

Page 3: ...e cleaning products of any kind on this product especially those containing ammonia bleach or alcohol or those with any form of abrasive CARE AND CLEANING INSTRUCTIONS 2 1 2 1 1 FOR CARE AND MAINTENANCE The water in certain areas of the world can be very caustic standing water around the product can cause damage Be sure to remove standing water with a dry soft cloth as soon as possible For polishe...

Page 4: ...nd finishes of the Elkay Residential brand faucets are free from defects in materials and workmanship for the life of the product if purchased after 1996 This warranty covers the original consumer purchaser of the product only If the product should leak or drip during normal use Elkay will provide free of charge a replacement cartridge For other defects in material or workmanship Elkay will at its...

Reviews: