Page 4
2000000556 (Rev. B - 06/22)
HAC8BLWFN_2A
Operation: Start-Up
Figure 6
Figure 7
BOTTLE FILLING UNIT
WALL MOUNTING PLATE
from the wall mounting plate installed on wall. Make sure round boss in gasket fits in hole of basin.
(See Fig. 6).
9.
Once Bottle Filler is installed on wall plate tabs, water line, wire(s) and power cord are installed
properly, push top of Bottle Filler toward wall and line up top cover two (2) holes.
10. Reinstall Top Cover on Bottle Filler (See Fig. 3) with two mounting screws from step 1 above.
Caution: Do not over tighten screws.
11.
Install remaining tube insulation to the water line from bottle filler, connect Bottle Filler waterline inside
of the water cooler by connecting the 3/8” (10mm) water line to the tee.
12.
Install filter cartridge, remove filter from carton, remove protective cap, attach filter to filter head by
firmly inserting into head and rotating filter clockwise. NOTE: If existing plumbing rough in locations
(Drain, Water In, and Electric Supply) do not allow the filter to be mounted inside the cooler cabinet
the filter can be installed horizontally below the unit. A retrofit kit is available to mount the filter
beneath the cooler.
13.
Turn water supply on and inspect for leaks. Fix all leaks before continuing.
14.
Once unit has been inspected for leaks and any leaks found corrected, plug Bottle Filler and unit into
wall. Be sure to reinstall fuse to the circuit or switch the circuit breaker back to the “ON” position.
15.
Once power is applied to Bottle Filler, the GREEN LED light should illuminate showing good filter
status along with the LCD Bottle Counter.
16.
Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify
water dispenses. Note: The first initial dispenses might have air in line which may cause a sputter.
This will be eliminated once all air is purged from the line.
17. Once unit tests out, install Lower Panel back on water cooler(s). Unit is now ready for use.
1.
Turn on the building water supply and check all connections for leaks.
2.
Ensure unit is plugged into electrical supply. Unit must have electrical power to have water flow from bottle filler.
WARNING
3.
Purge air from all water lines by:
• Depressing button or front push bar of cooler/fountain.
NOTE:
Steady stream of water assures all air is removed.
4.
Recheck all water and drain connections with water flowing through system.
5.
Stream height is factory set for 45-50 PSI (3.1 - 3.4 Bar ) supply. If supply pressure varies greatly from this, readjust stream height to approximately
1-1/2” (38mm) above the bubbler guard by turning adjustment screw, accessible by removing front push panel.
6.
Replace the front panel and secure by retightening four (4) screws.
7. If a taste, odor or sediment problem is prevalent, try installing our water filter module.
39
38