INSTALLATION INSTRUCTIONS

1.  

Install

 remote chiller. Remove front panel of chiller. Remove and discard cardboard inner pack from between compressor and

    side panel. Slide chiller onto the shelf and position it to the left side of shelf. (See Figure 6)

    

NOTE:

 Building construction must allow for adequate air flow on both sides, top, and back of chiller.  See chiller instructions for

    additional instructions.

2. 

Make

 water supply connections. Install a shut-off valve and union connection to building water supply (valve and union not

    provided). Turn on the water supply and flush the line thoroughly.

3. 

ERPA MODELS:

 Make connection between remote chiller and building supply line. Inlet port is marked on the chiller (1/4" O.D.

    copper tube). Bend the copper tube (provided) at an appropriate length from chiller to opening in frame. Install a 1/4" x 3/8" union

    (provided) on the marked chiller inlet port. Connect building supply line to union. (See Figure 7)

    

LPTEA MODEL:

 Mount filter head assembly to side of chiller (See Figure 9). Make connection between filter and building supply

    line (3/8" O.D. tube not provided). Inlet port is marked on the chiller (1/4" O.D. copper tube). Install a 1/4" x 1/4" union (provided).

    Bend the copper tube (provided) at an appropriate length from the filter and connect to the union on the chiller. (See Figure 8).

 4. 

Hang

 the upper panel on the mounting frame hanger. Align holes in the panel with the holes in the mounting frame. Be sure that

    panel is engaged with hanger at top of frame before releasing it.

 5. 

Install

 the fountain. Remove access cover plate on underside of fountains and save the screws. Mount the fountain to the

    upper panel and the wall frame with (4) 5/16" x 1 3/4" (44mm) long bolts and nuts (provided). Install spacers on bottom two bolts.

    Tighten securely.

 6. 

Attach

 waste tube (1 1/4" OD) to 1 1/4" OD slip trap (provided by others).

 7. 

ERPA MODELS:

 Make connections between remote chiller outlet tube and fountain strainer. Outlet port is marked on the chiller

    (3/8" O.D. copper tube). Install a 3/8" x 3/8" union (provided) on the marked chiller outlet port. Insert the 3/8" unplated copper

    water line (provided) into the union and the inlet side of the strainer by pushing it in until it reachs a positive stop, approximately

    3/4" (19mm). Connect 1/4" copper tubing coming from fountain to the strainer. Turn on water supply and check for leaks. 

DO NOT

     SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT.

 (See Figure 6).

    LPTEA MODEL:

 Make connections between remote chiller and fountain. Outlet port is marked on the chiller (3/8" O.D. copper

    tube). Install a 3/8" x 3/8" union (provided) on the marked chiller outlet port. Insert the 3/8" unplated copper water line (provided)

    into the union. Install a 1/4" x 3/8" union (provided) on the 3/8" copper tube and connect to the 1/4" copper tubing coming from the

    fountain. Turn on water supply and check for leaks. 

DO NOT SOLDER TUBES INSERTED INTO THE UNIONS AS DAMAGE TO

    THE O-RINGS MAY RESULT. 

(See Figure 8).

 8. 

These

 products are designed to operate on 20-105 PSIG supply line pressure. If inlet pressure is above 105 PSIG, a pressure

    regulator must be installed in the supply line.  Any damage caused by reason of connecting these products to supply line

    pressures lower than 20 PSIG or higher than 105 PSIG is not covered by warranty.

 9. 

Make

 electrical connections to the chiller. See chiller instructions.

10. 

Check

 stream height from bubbler. Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, turn

    adjustment screw on regulator (Item 12). Clockwise adjustment will raise stream height and counter-clockwise

     will lower stream height. For best adjustment stream should hit basin approximately 6 1/2" from the bubbler.

11. 

Mount

 lower panel. Loosen  the (2) #10-24 x 5/8" (16mm) screws at frame bottom lip. Slide upper tongue of lower panel under

    lower edge of already installed upper panel.  Tighten previously loosened screws securely.

12. 

Replace

 bottom access panel to fountain basin using screws provided. Tighten securely.

TROUBLE SHOOTING AND MAINTENANCE

1. 

Orifice Assy:

  Mineral deposits on orifice can cause water flow to spurt or not regulate.  Mineral deposits may be removed

    from orifice with a small round file not over 1/8" diameter or a small diameter wire. 

CAUTION:

 Do not file or cut orifice materials.

2. 

Stream Regulator:

 If orifice is free of material deposits, regulate flow according to instruction 10 stated above.

3. 

Actuation of Quick Connect Water Fittings:

  Cooler is provided with lead-free connectors which utilize an o-ring water

   seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing (See Fig. 2)

   To insert tubing, push tube straight into the fitting until it reaches a positive stop, approximately 3/4".

4. 

Caution: 

Cleaning of Bronzetone Models requires special care. Outer surfaces must be cleaned with a mild detergent or

   mixture of vinegar and water only, rinsed and wiped dry. Abrasive and acidic cleaners may eventually damage the

   Bronzetone finish.

CHILLER

INLET

CHILLER

OUTLET

32

43

33

TO BUBBLER

TO BUBBLER

WATER

INLET

CHILLER

OUTLET

32

34

LPTEA8C /LPTEA8RAC TUBE ROUTING

FIG. 8

43

43

TO BUBBLER

43

Summary of Contents for ERPA2-8C

Page 1: ...OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELEC TROLYSIS WHICH CAUSESAMETALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION ISAVOIDABLE BY USING THE PROPER MATERIALSAS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYST...

Page 2: ... ERPAVR2 8C ERPAVR2 8RAC LPTEA8C LPTEA8RAC FIG 6 PAGE 2 LEGEND A 3 8 O D TUBE CONNECT CHILLER WATER OUTLET B 3 8 O D TUBE CONNECT CHILLER WATER INLET SHUT OFF VALVE BY OTHERS C 1 1 4 TRAP NOT FURNISHED D ELECTRICAL INLET LPTEA8C LPTEA8RAC ...

Page 3: ...S MAY RESULT See Figure 6 LPTEA MODEL Make connections between remote chiller and fountain Outlet port is marked on the chiller 3 8 O D copper tube Install a 3 8 x 3 8 union provided on the marked chiller outlet port Insert the 3 8 unplated copper water line provided into the union Install a 1 4 x 3 8 union provided on the 3 8 copper tube and connect to the 1 4 copper tubing coming from the founta...

Page 4: ...ong Cover Plate Long Bronzetone Speed Nut Basin Swirlflow Basin Swirlflow Bronztone Strainer Screw 10 24 X 62 HHMS Strainer Ferrule Assembly Strainer Ferrule Assy Bronzetone Gasket Tailpipe Gasket Tailpipe Waste Arm Tube Water In Poly Tubing 48 Cut To Length Bubbler VR Model Only Gasket VR Model Only Bubbler Nipple VR Model Only Bolt 5 16 18 x 1 75 Lg Nut Hex 5 16 18 Spacer 51349C 56044C 40322C 45...

Reviews: