Elkay ER52Y Installation, Care & Use Manual Download Page 3

1000003022 (Rev. A - 10/15)

ER5_2D

PAGE 3

For Replacement Parts, contact your local distributor or visit our website www.HalseyTaylor.com

2222 Camden Court – Oak Brook, IL 60523 U.S.A – 630.574.3500

Service

For proper and safe servicing, please read these instructions completely.

       •        All Service and Maintenance must be performed by an authorized service personnel. 

       •        Disconnect electrical supply to the unit before any service work to reduce risk of electrocution. 

       •        Shut off water supply serving the unit before any service work to reduce risk of water damage.

DANGER

CAUTION

       •        Tools/Items required but not provided, for Servicing:

                       o     Safety Glasses

                       o     Protective Gloves

                       o     1/4" (6.4mm) Socket Wrench or Flat Head Screwdriver

1.         Temperature Control: Factory set for 50ºF ± 5º (10ºC ± 5º) water under normal conditions. To adjust water temperature, turn screw on Item

            No. 14 clockwise for colder, counter clockwise for warmer. 

Service: Adjustments

Service: Inspection/Cleaning

       •        Inspect Water Chiller twice each year for proper operation and performance.

       •        Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and reassembly and return to service practices.

2.         Condenser Fan Motor

: Confirm condenser fan turns freely. If the condenser fan does not spin freely, have an authorized service personnel

            replace.

3.         Ventilation

: Cabinet louvers and condenser fins should be periodically cleaned with a brush, air hose or vacuum cleaner. Cleaning should

            be done twice each year or more frequently if needed due to environment. Excess dirt or poor ventilation can cause no cold water and

            compressor cycling on the compressor overload protector.

4.         Water Flow

: Confirm proper water flow. If water flow is slow, inspect filter or inline strainer for restriction. Replace filter cartridge if required.

            Disassemble inline strainer and clean if required.

5.         Lubrication: Motors are lifetime lubricated.

6.         Actuation of Quick Connect Water Fittings: Chiller is provided with

            lead-free plug which utilizes an o-ring seal. To remove plug from

            Chiller, relieve water pressure, pull the collar towards the fitting and

            pull the fitting off the tube. To install plug, push fitting straight onto

            tubing until it reaches a positive stop, approximately 3/4”(19mm). 

Replacement Parts: Parts List

ITEM 

NO. 

PART

NO.

DESCRIPTION

8, 9 14

2

1

13

18

3, 4, 5, 6, 7

10

12

22

20

15

11

16

19

17

23

21

1

2

3

4

5

6

7

8

9

10

*11

12

13

14

15

16

17

18

19

20

21

22

23

NS

27666C

31513C

31430C

30664C

20282C

70018C

70009C

66303C

50189C

66201C

36243C

98748C

27667C

35882C

28399C

0000000255

66754C

27665C

70772C

27669C

27663C

28400C

27664C

27668C

Cover - Terminal Box

Control - Freeze Protect

Motor - Fan

Fan - Blade

Fan - Bracket

Fan - Nut

Screw - Motor Mounting

Condenser

Shroud

Drier

Compr. Serv Pak

Kit - Electrical (Relay/Cover/Overload)

Terminal Box Assy

Control - Cold

Base Assy
Kit - Compr Mtg Hdwe/Grommets/Clips/Studs

Evaporator - Assy

Cover - Insulation Box

Drain Plug

Grille - Front

Panel - Insul Box (Rear)

Panel - End

Box - Insulation (Front)

Grille - Rear (Not Shown)