microwave
timer - three wire
Product:
380A-1 Three wire
Rating at 240V ac
• Incandescent 16A • Compact Fluorescent 16A
• Resistive 16A • Fluorescent 16A • Time Delay 2min - 2h
1.
Ensure the mains power is switched off before any wiring takes place.
2.
Fit the back box to the wall for mounting using appropriate screws and
fixings (not supplied).
3.
Set the dip switches to the required time settings (See diagram 2).
4.
Connect the Live In, Live Out (Switch Live) and the Neutral into the marked
terminals (See diagram 1).
5.
To adjust lux level, locate lux level adjuster on the circuit board where the
word LUX is printed. Turn anticlockwise for plus + and clockwise for minus -.
6.
To adjust sensitivity, locate SEN on the opposite side of the circuit board
turn clockwise for plus + and anticlockwise for minus -.
7.
Please ensure white faceplate is attached before initialisation with holes at the top.*
8.
Apply the mains power. Your load will turn on and a red light will begin flashing for 2 minutes and then will flash rapidly for 1 minute.
At the end of this 3 minute cycle the load will turn off. The load will switch on again once further movements are detected.
9.
Please note the red LED should be clearly seen through the hole in the faceplate. The unit is supplied with the default setting of max
lux and sensitivity levels.
N.B. For flush mounting please ensure that it fits into a 35mm backbox.
IMPORTANT NOTICE
All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE 17th Edition Wiring regulations BS7671:2008.
Call +44 (0) 1675 468222 or click www.elkay.co.uk
microwave
timer
Diagram 1
Wiring diagram for a three wire Microwave unit
(For additional products to be added see Diagram 3).
microwave
timer fitting and operating instructions
N SL L
energy
sense
* If faceplate is clipped on the wrong way Lux level adjustment
will not work correctly (See TOP markings).
TOP
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
ON DIP
ON DIP
ON DIP
ON DIP
50 mins
60 mins
70 mins
80 mins
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
ON DIP
ON DIP
ON DIP
ON DIP
2 mins
5 mins
10 mins
15 mins
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
ON DIP
ON DIP
ON DIP
ON DIP
90 mins
100 mins
110 mins
120 mins
Diagram 2
Please note that the black bar denotes the position
of the dip switch.
8476 ELKAY MICROWAVE TIMER INSTRUCTIONSv6_Layout 1 02/11/2009 09:22 Page 1