97162C (Rev. H - 10/02)

PAGE 4

EFRC8C-A   EFRC8CDC-A   EFRC12C-A   EFRC12CDC-A   LJNE8C-A   LJNE12C

INSTALLATION INSTRUCTIONS

1.  Remove 

shipping brace from mounting box and discard.

2.  Fasten 

mounting box into wall cutout using screws or bolts (provided by others) through the holes or knock

     outs provided on each side of the mounting box.  (See Fig. 1 or 2)

3.  Install

 fountain body to mounting box using #10 x .63” (16mm) PHSM screws and large clips provided.

4.  Place

 refrigeration package into mounting box and connect water lines. (See Page 5 for details)

5.  Water

 inlet is 3/8" O.D. and waste tube is 1-1/4" O.D.  Contractor is to supply waste trap and service stop

     valve in accordance with local codes.

6.  Connecting

 lines to be unplated copper and thoroughly flushed to remove all foreign matter before connecting

     to refrigeration package.  The furnished strainer (Item 18) should be added to the supply line.

7.  Connect

 the refrigeration package to the supply line service stop valve.  Connect supplied fountain (internal

     plumbing) tubes as shown in figures 3, 4, 5, or 6.  Remove any burrs from water tubes before inserting into

     fittings.  (See Figs. 13 and 14) 

DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE

     TO THE O-RINGS MAY RESULT.

8.  Electrical

:  Insure power supply is identical in voltage, hertz, and phase to that specified on the refrigeration

     package serial plate.  Never wire compressor directly to the power supply.

9.  Turn

 water supply on and check thoroughly for leaks.

10. Release

 air from tank by depressing push button; a steady stream of water assures all air is removed.

11. Re-check

 for leaks.

12. Stream

 height is factory set at 35 PSI. If supply pressure varies greatly from this, turn adjustment screw on

      regulator (Item 14).  Clockwise adjustment will raise the stream height and counter-clockwise adjustment

      will lower stream height.  For best adjustment, stream should hit basin approximately 6-1/2" from the bubbler.

13.  Rotate 

fan blade on refrigeration package to insure proper clearance and free fan action.

14.  Connect

 power supply.

15.  Install

 grill using #8 x 1.00" (25mm) PH screws and small clips provide

d.

TROUBLE SHOOTING AND MAINTENANCE

1. Orifice Assy:

  Mineral deposits on orifice can cause water flow to spurt or not regulate.  Mineral deposits

    may be removed from orifice with a small round file not over 1/8 diameter or a small diameter wire.

    

CAUTION:  Do not file or cut orifice materials.

2. Actuation of Quick Connect Water Fittings:

  Cooler is provided with lead-free connectors which utilize

    an o-ring water seal.  To remove tubing from the fitting, relieve water pressure, push in on the gray collar

    while pulling on the tubing (See Fig. 13).  To insert tubing, push tube straight into the fitting until it reaches

    a positive stop, approximatley 3/4".

Summary of Contents for EFRC8CDC-A

Page 1: ... for future reference IMPORTANT INSTALLER PLEASE NOTE THE GROUNDING OF ELECTRICAL EQUIPMENT SUCHAS TELEPHONE COMPUTERS ETC TOWATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTOAFOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSESA METALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CO...

Page 2: ...CATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB 1 1 2 38mm OUT FROM WALL SHUT OFF BY OTHERS BOTH SIDES B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D DRAIN BOTH SIDES C ELECTRICAL SUPPLY LOCATION BOTH SIDES NOTES 1 THERE ARE HOLES AND KNOCKOUTS PROVIDED ON EACH SIDE OF THE MOUNTING BOX THAT ARE INTENDED TO BE USED TO MOUNT THE BOX USE SIX SCREWS OR BOLTS NOT PROVIDED ...

Page 3: ...BE CONNECT STUB 1 1 2 38mm OUT FROM WALL SHUT OFF BY OTHERS LEFT SIDE ONLY B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D DRAIN LEFT SIDE ONLY C ELECTRICAL SUPPLY LOCATION BOTH SIDES WATER AND DRAIN CONNECTIONS MUST BE MADE FROM LEFT SIDE ONLY NOTES 1 THERE ARE HOLES AND KNOCKOUTS PROVIDED ON EACH SIDE OF THE MOUNTING BOX THAT ARE INTENDED TO BE USED TO MOUNT THE BOX USE SIX SCREWS OR BOLTS NOT...

Page 4: ...e hertz and phase to that specified on the refrigeration package serial plate Never wire compressor directly to the power supply 9 Turn water supply on and check thoroughly for leaks 10 Release air from tank by depressing push button a steady stream of water assures all air is removed 11 Re check for leaks 12 Stream height is factory set at 35 PSI If supply pressure varies greatly from this turn a...

Page 5: ... Rev H 10 02 PAGE 5 EFRC8C A EFRC8CDC A EFRC12C A EFRC12CDC A LJNE8C A LJNE12C FIG 3 FIG 4 FIG 5 FIG 6 17 18 16 18 17 18 17 16 18 EFRC8C EFRC8C W GLASS FILLER EFRC12C EFRC12C W GLASS FILLER 44 44 44 44 17 17 ...

Page 6: ...RC12C A EFRC12CDC A LJNE8C A LJNE12C 10 11 12 13 15 5 1 6 9 14 4 3 8 7 2 28 30 28 34 32 33 FIG 8 FIG 7 FIG 9 NOTE WHEN INSTALLING REPLACEMENT BUBBLER AND PEDESTAL TIGHEN NUT ITEM 15 ONLY TO HOLD PARTS SNUG IN POSITION DO NOT OVER TIGHTEN BASIN BASIN ...

Page 7: ...97162C Rev H 10 02 PAGE 7 EFRC8C A EFRC8CDC A EFRC12C A EFRC12CDC A LJNE8C A LJNE12C 16 31 43 15 DISPENSER DISPOSAL 26 29 17 39 40 41 36 38 35 42 15 26 27 FIG 12 FIG 11 FIG 10 37 ...

Page 8: ...38 39 40 41 42 43 44 Retaining Nut Tailpipe EFRC8 EFRC8F Tailpipe EFRC8CD Precooler EFRC12 EFRC12F Precooler EFRC12CD Strainer Button Nut Cover Hex Nut Ferrule Gasket Regulator Holder Bubbler Assy Orifice Assy Housing Assy Pedestal Regulator Locknut 3 8 18 Tee 1 4 Union 1 4 Strainer Screw 10 x 63 PHSM Screw 8 x 1 00 PH Speed Nut 8 Clip Speed Fountain Fountain GF Dispenser Disposal Grill O ring Gla...

Reviews: