background image

Page 4

97460C (Rev. SIB - 6/06)

4595_FTN

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620

PRINTED IN U.S.A.

DESCRIPTION

100147140560
100322740560
101570540560

15005C
15013C

170705042830

40048C
40089C

400942308640

98287C
40169C
40250C
45476C
50986C
55913C
55996C
56092C
56121C

600985551640

61313C
66346C
70682C
70683C
75588C
75589C

1
2
3
4
5
6
7
8

      9 - A

      9 - B

10

11

12
13
14
15
16
17
18
19
20
21
22
23
24

PART NO.

Drain Gasket
Bubbler Gasket
Drain Gasket
Regulator Retaining Nut
Bubbler Tube Assy.
Basin
Button
Cover Nut
Bubbler
Bubbler Assembly
Hex Nut 1-5/16-20UN
Tailpipe 1-1/4" x 5-3/8"
Drain Tube
Regulator Holder
Drain Adapter
In-Line Strainer
Poly Tubing (Cut To Length)
Drain Elbow 1-1/4"
Drain Plug Assy.
Regulator
Drain Tube
Tee - 1/4
Union - 1/4
Slip Joint Nut 1-1/4"
Gasket

ITEM NO.

PARTS LIST

FIG. 6

NOTE: WATER FLOW

DIRECTION

BUILDING WATER INLET

SERVICE STOP
(NOT FURNISHED)

1/4" O.D. TUBE
WATER INLET
TO FOUNTAIN

3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY

TROUBLE SHOOTING AND MAINTENANCE

Orifice Assy:

  Mineral deposits on orifice can cause water

flow to spurt or not regulate.  Mineral deposits may be
removed from the orifice with a small round file or small
diameter wire.  

CAUTION:  DO NOT

 file or cut orifice

material.

Stream Regulator:

  If orifice is clean, regulate flow as in

"STREAM HEIGHT ADJUSTMENT"

 instructions on page

3.  If replacement is necessary, see parts list for correct
regulator part number.

Actuation of Quick Connect Water Fittings:

  Fountain is

provided with lead-free connectors which utilize an o-ring
water seal.  To remove tubing from the fitting, relieve water
pressure, push in on the gray collar while pulling on the
tubing (See Fig. 5).  To insert tubing, push tube straight
into fitting until it reaches a positive stop, approximately
3/4".

FIG. 5

4595_FTN

Summary of Contents for 4595

Page 1: ... THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM INSTALLER General Installation Tips 1 Water supply 3 8 O D unplated copper tube Waste 1 1 4 IPS Contractor to supply waste trap and service stop valve in accordance with local code 2 Connecting lines to be made of unplated copper and should be thoroughly flushed to remove all foreign matter before being connected to fountain This fountain is manufact...

Page 2: ...3 Install shut off valve on water supply Valve not furnished 4 Locate and install fountain using 3 8 minimum screws or bolts Screws or bolts not furnished CAUTION This fountain is rated for inlet water pressure of 20 105 PSI A pressure reducing regulator should be used if the inlet water supply exceeds 105 PSI 5 Connect water supply and fountain drain Water connection and drain must comply with lo...

Page 3: ...eatly from this remove items 7 and 8 See Fig 3 and adjust screw on item 19 Clockwise adjustment will raise stream and counter clockwise adjustment will lower stream For best adjustment stream should hit basin approx 6 1 2 from bubbler FIG 2 FIG 3 FIG 4 8 4 19 13 10 7 11 22 16 16 16 15 12 1 20 23 3 1 14 24 23 22 5 2 2 9 B 6 3 2 5 16 18 21 16 BUBBLERDETAIL ...

Page 4: ...ARTS LIST FIG 6 NOTE WATER FLOW DIRECTION BUILDING WATER INLET SERVICE STOP NOT FURNISHED 1 4 O D TUBE WATER INLET TO FOUNTAIN 3 8 O D UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY TROUBLE SHOOTING AND MAINTENANCE Orifice Assy Mineral deposits on orifice can cause water flow to spurt or not regulate Mineral deposits may be removed from the orifice with a small round file or small diameter wire CA...