Elk ELK-6030 Installtion And Setup Manual Download Page 4

Page 4

ELK-6030 PIR Installation Manual

LIMITATIONS

While the 6030 Passive Infrared (PIR) Motion Detector
is a highly reliable intrusion detection device, it does not
offer guaranteed protection against burglary.  Any
intrusion detection device is subject to compromise or
failure to warn for a variety of reasons:

PIR Detectors can only detect movement within a
specific coverage area as diagrammed in this manual.
To detect movement, the PIR Detector senses the
infrared energy that is emitted from an intruder moving
across the sensor's field of view.

PIR Detectors do not provide volumetric area protection.
They create multiple beams of protection.  Intrusion can
only be detected in unobstructed areas covered by
those beams.

PIR Detectors cannot detect motion or intrusion that
takes place behind walls, ceilings, floors, closed doors,
glass partitions, glass doors, or windows.

The radio transceiver only provides communications.
It does not have anything to do with detecting motion.

The 6030 PIR is not a Life Safety device.  The Security/
Convenience Light feature is not a substitute for, nor
should it ever be utilized as a substitute for a visual
notification appliance.

PO Box 100    3266 US Hwy 70 West
Hildebran, NC  28637
828-397-4200      828-397-4415 Fax    http://www.elkproducts.com

Printed in USA
L645  Rev. A  9/25/2013

A deluxe 90° swivel bracket may be purchased and used
in lieu of the standard swivel bracket.  This bracket has
a short extended arm and allows the sensor to be aimed
at up to a 90° offset from the wall or base.  This bracket
also allows the sensor to be drop mounted from a ceiling.

OPTIONAL DELUXE 90° SWIVEL MOUNT

ANTI-TAMPER SWITCH

This switch detects the separation of the front housing
from the backplate, resulting in a signal being transmitted
to the control/transceiver that will cause the associated
zone to become violated.  Snapping the front housing
back onto the backplate will transmit a restoral.

FUNCTIONAL 'SYSTEM' TESTING

A system test should be done by physically walking
across the 6030 coverage pattern while the system is
fully armed.  NOTE: Allow time for the Sleep Cycle Timer
to expire before testing.  Always notify the Central
Monitoring Station prior to performing any testing.

BATTERIES

The 6030 holds 2 x CR123A Lithium batteries.  The
estimated service life is 5 to 7 years in a typical residential
installation with the Sleep Cycle set to LG (Long),

Battery #1 (lower) is supervised for low voltage.  When
the sensor detects the voltage has reached 2.6 VDC or
less (under load), a Sensor Low Battery trouble will be
transmitted to the control/transceiver.  This trouble will
be attached to all future transmissions until fresh new
batteries are installed.  Battery #1 is the primary power
source for all critical functions (motion detect and radio
transmission) of the 6030 sensor.

Battery #2 (upper) is not-supervised for low voltage.
This battery is a secondary (reserve) power source for
the 6030 critical functions, but it is the primary (sole)
power source for the White Security/Convenience LED.
The White Security/Convenience LED will not operate
without a good battery installed in Battery #2 location.

We strongly recommend installing a battery in both
locations.  These 2 batteries are electrically isolated in
such a way that critical functions of the 6030 can draw
power from either battery, but the White Convenience
LED can only draw power from Battery #2.

To clear a sensor low battery trouble condition, remove
old batteries and WAIT AT LEAST 20 seconds before
installing new batteries.  Once the new batteries are
installed, trip the sensor a couple of times.  This should
send an "all good" and clear the low battery trouble.

Caution: Excessive use of the White Security/
Convenience LED will reduce the life of Battery #2.
More importantly, because the 6030 sensor is able
to tap into Battery #2 for secondary power, any
reduction of its life naturally reduces the overall
operational life of the sensor.  If maximum sensor
operational life is the top priority, the Security/
Convenience LED may be disabled by turning DIP
Switch #3 OFF

.

BATTERY REPLACEMENT

Use only approved 3V Lithiums.  Replace both batteries
at the same time and with same date code if possible.
Replacements can be obtained from Alarm Distributors.

1. Remove sensor from back housing.
2. Remove both old batteries from sensor.
3.

WAIT AT LEAST 20 SECONDS 

before installing new

batteries.  

Observe correct polarity

 when installing

new batteries.  Do not bend or damage the metal
battery holder contacts.  Approved 3.0 Lithium
Batteries are:  Panasonic CR123A,  Duracell DL123A,
Varta CR123A,

4. Re-test sensor operation with the control.

BATTERY WARNING:  Risk of fire, explosion
and burns.  Do not attempt to recharge or
disassemble.  Do not incinerate or expose to
heat above 212° F (100° C).  Dispose of used
batteries properly.  Keep away from children.

ACTIVATING THE WHITE

SECURITY/CONVENIENCE LIGHT 

TM

The Security/Convenience Light (White LED) illuminates
out the sensor front and has several operating modes:
Quick blip in walk test when motion is detected.  Flash
during audible alarms.  On Solid when control is armed to
Away and motion is detected.  On Solid when output 4 is
ON and motion is detected.  Flash by command from
control.  Solid ON by command from control.  DIP Switch
#3 allows the White LED to be disabled for most modes.

Note: This LED is never disabled in Walk Test.

Note: Most of the Security/Convenience Light modes
require  two-way commands from the M1 Control.  Up
to 8 seconds (typical) may be required before a two-
way command is received.  Be prepared for this delay
during testing and operation.  Do not expect
instantaneous reaction on these commands.

y

  Flash during audible alarms

Audible alarms (

not Silent 24hr Police)

 will make the

White LED flash.  This continues until: the alarm cutoff
timer expires, Control is disarmed, Battery #2 expires,
or a rule based White LED command expires.  If motion
is detected, the flash will change to solid for about 17
seconds.  Audible alarm activation can only be disabled
by removing Battery #2, NOT via DIP Switch #3.

y

  On Solid if Armed to Away and Motion Detected

Any motion detected while the control is armed to AWAY
mode will make the White LED turn On solid for about
18 seconds.  

NOTE: DIP Switch #3 must be ON

Activations using ElkRP Rules

The White LED can be controlled using  ElkRP Rules and
M1 Outputs 4, 5, & 6.  These 3 outputs are not physically
available on the M1 board and can therefore be used as
phantom outputs.  The 6030 detects the state of these
"phantom" outputs and responds as follows:

y

  On Solid if Motion Detected 

 [M1 Output 4]

If Output 4 is ON, any detected motion makes the White
LED turn On for about 17 seconds.  Continued motion
will restart the time.  Use a ElkRP rule to turn Output 4
On for a time, date, or condition.  

When Sunset - Then

Turn Output  4 On

   Use a second ElkRP rule to turn

Output 4 Off when this LED action is no longer desired.

When Sunrise - Then Turn Output 4 Off

   

NOTE: DIP

Switch #3 must be ON.

y

  Flash - on command 

   [M1 Output 5]

Turning M1 Output 5 On commands the 6030 to flash
its White LED for about 30 seconds.  Use a ElkRP rule
to turn Output 5 On for a specific time, date, or condition.

When 5:30PM (closing time?) - Then Turn Output 5 On
for 38 seconds

.  The 38 seconds allows for a full 30

seconds of flash and then turns the output back off.  To
repeat this command the output should remain Off for
at least 8 seconds.   

NOTE: DIP Switch #3 must be ON

y

  Solid On - on command

   [M1 Output 6]

Turning M1 Output 6 On commands the White LED to
go Solid On for about 17 seconds.  Use a ElkRP rule to
turn Output 6 On for a specific time, date, or condition.

When Entry Delay Starts - Then Turn Output 6 On for 25
seconds

   The 25 seconds allows for a full 17 seconds

of solid and then turns the output back off.  To repeat
this command the output should remain Off for at least
8 seconds.   

NOTE: DIP Switch #3 must be ON

Rule Examples for the Security/Convenience Light:

Whenever Sunset

        Then Turn Output 4 On.
Whenever Sunrise

        Then Turn Output 4 Off.
Whenever Time is 6:00pm (e.g. flash for dinner time)

       Then Turn Output 5 On for 38 seconds.
Whenever Entry Delay Starts

       Then Turn Output 6 On for 25 seconds.

FCC AND IC COMPLIANCE STATEMENT:

This device complies with Part 15 of the FCC Rules and Industry

Canada License-Exempt RSS Standards.  Operation is subject to the

following two conditions: (1) This device may not cause harmful

interference, and (2) This device must accept any interference received,

including interference that may cause undesired operation.

Under Industry Canada regulations, this radio transmitter may only

operate using an antenna of a type and maximum (or lesser) gain

approved for the transmitter by Industry Canada. To reduce potential

radio interference to other users, the antenna type and its gain should

be so chosen that the equivalent isotropically radiated power (e.i.r.p.)

is not more than that necessary for successful communication.

Conformément à la réglementation d’Industrie Canada, le présent

émetteur radio peut fonctionner avec une antenne d’un type et d’un

gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie

Canada. Dans le but de réduire les risques de brouillage radioélectrique

à l’intention des autres utilisateurs, il faut choisir le type d’antenne et

son gain de sorte que la puissance isotrope rayonnée quivalente

(p.i.r.e.) ne dépassepas l’intensité nécessaire à l’établissement d’une
communication satisfaisante.

ELK-6030     Wireless PIR

FCC ID: TMAELK-6030X

IC: 4353A-6030X

NOTE:   ELK PRODUCTS IS NOT RESPONSIBLE FOR ANY CHANGES

OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY

RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD

VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.

Backplate

Deluxe 90°

Swivel

Bracket

Locking

Disc

Figure 8. Deluxe 90° Swivel Bracket

(Separate purchase  P/N: ELK-603022)

LIMITED WARRANTY

The 6030 Wireless PIR Sensor is warranted to be free
from defects and workmanship for a period of 2 years
from date of manufacture.  Batteries used with wireless
devices are not warranted.  Elk makes no warranty,
express or implied, including that of merchantability or
fitness for any particular purpose with regard to batteries
used with wireless devices.  Refer to Elk’s website for
full warranty statement and details.

Reviews: