background image

Page 2 

ELK-P1215 / P1215K Installation Manual

DC

 

Output

12

 

Volts

 

at

 

1.5

 

Amps

 

Maximum

+

ON

OFF

MASTER

 

SWITCH

12V

 

SLA

BATTERY

ELK

P1

21

5C

B

12

VD

C

 

CHARG

ER

 

BD

  

W/SUP

V

 

+

 

CUT

O

FF

M

AX

.

 

1.5A

Master

 

Power

 

Switch

Turns

 

On/Off

 

the

 

DC

 

Input

 

and

 

Battery

+

Battery

 

Wires

 

to

 

Sealed

 

Lead

 

Acid

 

Standby

 

Battery

(+)

 

Red

    

(

)

 

Black

ELK

P1417

NEG

+

NEG

12VDC

 

OUT

+

SUP

+

+

LED

 

(D4)

 

is

 

used

 

as

 

circuitry

 

voltage

 

reference

 

only

 

and

 

is

 

not

 

intended

 

as

 

a

 

user

 

indicator

D4

Plugs

 

into

120

 

VAC

Note:

Output

 

Voltage

 

from

 

ELK

P1417

 

is

 

13.8

 

to

 

14

 

volts

 

DC

 

to

 

properly

 

charge

 

the

 

battery.

18AWG

 

min.,

 

10'

 

max

 

length.

DC

 

Input

**Use

 

ELK

P1417

 

ONLY**

DC

 

Power

 

Supply

ELK

P1417

F1

Faston

 

No.

 

187

 

Receptacles

Low

 

Battery

 

Supervision

Open

 

Drain

 

Output

 

that

 

pulls

 

to

 

ground

 

when

 

active.

(100mA

 

max)

Hookup

 

to

 

a

 

Security

 

Zone

.

End

 

of

 

Line

 

supervised

 

zone

 

using

 

2200

 

ohm

 

End

 

of

 

Line

 

Resistor

or

Remove

 

the

 

EOL

 

resistor

 

if

 

using

 

un

supervised

 

“normally

 

open”

 

zone.

ELK

P

12

VD

C

ELK

P1417

NEG

+

NEG

12VDC

 

OUT

+

SUP

NEG

Zone

 

Input

Security

 

Control

2200

EOL

ELK

P

12VDC

ELK

P1417

NEG

+

NEG

12VDC

 

OUT

+

SUP

12

 

Volts

 

DC

 

Sounder

+

+

LED

 

w/

 

required

 

1000

 

Ohm

 

Resistor

1000

LED

 

with

 

a

 

1000

 

ohm

 

resistor

 

or

 

12

 

Volts

 

DC

 

Sounder.

Example

 

hookups

 

for

 

alerting

 

a

 

low

 

battery

 

condition

OPERATION

 

Master Power Switch

This switch allows users to turn On or Off all power from the DC Output terminals for servicing.

 

Battery Supervision

 

If DC power from the ELK-P1417 is lost (i.e. AC power outage), the battery should continue to supply power to the ELK-P1215CB DC Output 

terminals. The battery's voltage is then monitored and if the voltage drops to 11 volts, then the –SUP low battery supervision output will turn ON 

(pull to ground) indicating a Low Battery condition. 

The -SUP output can be connected to an LED, 12 Volts DC Sounder, or a zone on a Security Control to report a low battery condition

.

Note: The –SUP output will only work until Low Battery Cutoff activates, (see below) at which time -SUP becomes inactive since all power to the 

P1215CB board will be completely shutoff. 

 

Low Battery Cutoff

If DC power from the ELK-P1417 continues to be lost for an extended period, the battery should continue to supply power to the ELK-P1215CB 

DC Output terminals. The battery's voltage is monitored during this time and if the voltage drops to 9 volts, then the battery will be Cutoff 

(disconnected) from the DC Output terminals. This helps to prevent “deep discharging” of the battery. 

Hookup

1. Observe 

correct polarity

 on all connections. 

2. The ELK-P1215CB circuit board can be mounted directly on top of a battery. (ELK-P1215K kit includes battery, sold separately for ELK-P1215 kit)

3. Connect the two battery wires to the battery terminals. Red wire to positive, Black wire to negative. 

4. Connect ONLY the ELK-P1417 Power Pack to the DC Input terminals. DO NOT CONNECT an AC TRANSFORMER. 

Two-conductor jacketed cable having Red and Black color coded wires are recommended, minimum 18 AWG. Maintain polarity if using 

non-color coded Zip cord. The consequences of using too small of a wire gauge, or extending the wire length beyond the recommended 

lengths may harm the ability to properly charge the battery, especially at full DC Output Load. 

    If using 18AWG - Do NOT exceed a distance of 10 feet.

    If using 16AWG - Do NOT exceed a distance of 15 feet. 

    If using 14AWG - Do NOT exceed a distance of 25 feet.

5. Plug the ELK-P1417 into a constant 120VAC source.

6. Connect the DC Output to the desired load.

7. Turn on Master Power Switch. 

Printed in USA    L654    8/28/2014