WARNING!  The RS485 Data Bus must NEVER have more 

that two (2) terminating resistors (jumpers).  Reliability and 

response will be affected!

ELK‐M1DBH Data Bus Hub connected to M1 Main Control

J2

J4

J6

J8

J1

J3

J5

J7

J9

Insert RJ45 Terminating Plug in 1st unused jack 

and terminate the control at JP3.  

DO NOT TERMINATE OTHER DEVICES

!

CAT5 Cables

NEG  ‐

DATA B

+12V

DATA BUS

+VKP

DATA B

DATA A

NEG
EGND

J1

J2

JP

RS

‐48

DAT

A B

US

DATA A

M1 Main Board

J10

 

 

Keypad 

 

 

Keypad 

 

 

Keypad 

Spare 1

Spare 2

+

A

B

Mount M1DBH inside control. 

Use 4 conductor cable to connect 

to the M1 Data Bus terminals. 

** SEE WARNING ABOVE 

NOTE: RS‐485 Data Bus Max. wire length is 4000 ft. Total.   Each CAT5 homerun from the M1DBH must be calculated as double  the 

running distance since the Data A & B lines travel out and then back (A1 & B1) where they are used to feed the next homerun.

The ELK‐M1DBH Data Bus Hub is for new installations where it is possible to run multiple CAT5/6 homerun cables.  The RJ45 jacks allow neat and 

organized connections.  The third wire pair in the CAT5/6 cable is used to return the DATA lines back from each device where they are used to feed 

the  next  adjacent  jack.    The  result  is  the  M1DBH  circuitry  daisy  chains  the  devices  by  series  connecting  the  DATA  lines  A  &  B.    Termination  is 

accomplished with a plug‐in RJ45 terminator (supplied).

The CAT5/6 Cables must be continuous from the M1DBH to the Device terminals or flying lead harness on all the Keypads. 

 

DO NOT MAKE ANY INTERMEDIATE SPLICES OR USE OTHER CABLES.  We strongly recommend using CAT5/6 cable with the 

largest available wire gauge.  The longer the distances the more important it is to have larger gauge wire.

Terminating 

Jumper

BLACK

RED

GREEN
WHITE

We recommend the M1DBH be mounted in close physical proximity to the M1 

Control where possible.  Two or more M1DBH boards may be connected in a 

single daisy chain by closely following the diagram at bottom of this page.

Refer to Keypad 

Instructions

for more info 

about Output 

and Zone Input

+

-

A

A1

B

B1

TO CONTROL

8 - Brown

7 - Wht/Brn

6 - Orange

5 - Wht/Blue

4 - Blue

3 - Wht/Org

2 - Green

1 - Wht/Grn

Pin1

RJ45 Plug

Blue pair is 

unused

Color Code for CAT5 Data Bus Cables

Pin1

Fro

nt 

vie

w

Optional programmable Zone Input

Optional programmable Output

-

+

N.C.

N.O.

2200

Ohm

EOL

To BLACK (Neg)

To BLACK (Neg)

Wht/Blue

Brown

Wht/Brn

Orange

Wht/Org

Green

 Blue

Wht/Grn

 RED +12V   

 BLACK (-) 
 GREEN

 WHITE

BROWN

BLUE

 

 

Keypad 

CAT5 

or 

CAT6 

Cable

To  (-) Neg 

Black wire

Load (50mA max)

I.E. LED, Relay

Do NOT exceed 4,000 ft. max. Data Bus 

distance.  The length of each CAT5 

homerun must be calculated as DOUBLE 

its physical length.

BLACK

RED

GREEN
WHITE

Proper (allowed) method for Daisy Chaining two or more ELK‐M1DBH Data Bus Hubs

J2

J4

J6

J8

J1

J3

J5

J7

J9

Insert RJ45 Terminating Plug in 1st unused 

jack and terminate the control at JP3.  

DO NOT TERMINATE OTHER DEVICES

!

CAT5 Cables

J10

 

 

Keypad 

 

 

Keypad 

A Crossover cable (diagram below) must be plugged into the first unused port of the first M1DBH to port J1 on the next M1DBH.

8 ‐ Brown

7 ‐ Wht/Brn

6 ‐ Orange

5 ‐ Wht/Blue

4 ‐ Blue

3 ‐ Wht/Org

2 ‐ Green

1 ‐ Wht/Grn

Pin1

RJ45 Plug

CAT5 or 

CAT6 Cable

Pin1

Fr

ont v

iew

1 ‐ Wht/Org

2 ‐ Orange

3 ‐ Wht/Grn

4 ‐ Blue

5 ‐ Wht/Blue

6 ‐ Green

7 ‐ Wht/Brn

8 ‐ Brown

Pin1

RJ45 Plug

Pin1

CROSSOVER CABLE

Orange pair "swaps" position  

with Green pair

J2

J4

J6

J8

J1

J3

J5

J7

J9

J10

 

 

Keypad 

 

 

Keypad 

CAT5 

Crossover

Cable

The data bus must appear as a single series circuit, meaning a single daisy chain type of 

connection.  Never attempt to multi‐spoke multiple M1DBH’s off a single M1DBH.

NO Terminating Plug here!

The CAT5/6 Cables must be continuous from the M1DBH to the Device terminals or flying lead harness on all the Keypads. 

 

DO NOT MAKE ANY INTERMEDIATE SPLICES OR USE OTHER CABLES.  We strongly recommend using CAT5/6 cable with the largest available wire gauge.  The 

longer the distances the more important it is to have larger gauge wire.

  WARNING: Never use any cable other than a good quality CAT5 cable with the M1DBH ports.  

Never attempt to splice or extend any of the M1DBH port cables using ordinary multi-conductor 

cable!  Elk Products will not support or approve any deviance from these instructions.   