Electrical Breaker Panel

NEUTRAL/

GROUND

BLOCK

240

240

240

240

120

120

120

120

120

120

120

120

WATER  HEATER

Installation of ELK-9100

at the Breaker Panel

Controlling Two 120VAC

Circuit Loads

Circuit 2

120 VAC Device

LINE SIGNAL

CIRCUIT1

CIRCUIT2

PUSH ON
PUSH OFF

ELK-9100

240V - 30A

HEAVY DUTY

ULTRAMATE

PVC

CONDUIT

LOAD

LOAD

NEUTRAL

GROUND

Note: 120V Breakers Must
be Side by Side to connect
to both L1 & L2 120v legs

i.e. Lights, Heater

Black & Blue Wires = Circuit 1
Red & Orange Wires = Circuit 2

Installation of ELK-9100 at the Load
Controlling One 240 VAC Circuit Load

ELK-9100

LINE SIGNAL

CIRCUIT1

CIRCUIT2

PUSH ON
PUSH OFF

ELK-9100

240V - 30A

HEAVY DUTY

ULTRAMATE

Electrical

Junction

Box

GND

TO

LOAD

BL

UE

RED

FROM

BREAKER

PANEL

L1

L2

LOAD

After disconnecting power, mount the 9100 and a 4" electrical
junction box near the load. (water heater, motor, etc.)
Disconnect the existing wiring from the load and route it into
the junction box.  Add wiring from the junction box to the load
and wire according to the diagram.

Note: The ELK-9100 cannot be powered
from GFCI Ground Fault Breakers.
However, GFCI Breakers can be utilized
on the output (load) side of the ELK-9100

Note: The ELK-9100 cannot be
powered from GFCI Ground Fault
Breakers. However, GFCI
Breakers can be utilized on the
output (load) side of the ELK-9100

Electrical Circuit

Breaker Panel

Figure 1

Figure 2

4"

Electrical

Junction

Box

(or other load)

(i.e. Water Heater)

This is the preferred method when the circuit breaker panel is flush
mounted, not accessible, or far away from the load.  It requires a
separate 4" electrical junction and wire connectors for safely
completing the installation.

Existing Wiring

to the Load

Remote from Load

Circuit 1

120 VAC Device

i.e. Lights, Heater

BLACK

RED

BLUE

ORANGE

NEUTRAL

GROUND

Not

Suitable

for Wet

Locations