BL
ACK
ORANGE
MAIN
Electrical Breaker Panel
NEUTRAL/
GROUND
BLOCK
240
240
240
240
120
120
120
120
120
120
120
120
WATER HEATER
Installation of ELK-9100
at the Breaker Panel
Controlling Two 120VAC
Circuit Loads
Circuit 2
120 VAC Device
LINE SIGNAL
CIRCUIT1
CIRCUIT2
PUSH ON
PUSH OFF
ELK-9100
240V - 30A
HEAVY DUTY
ULTRAMATE
PVC
CONDUIT
LOAD
LOAD
NEUTRAL
GROUND
Note: 120V Breakers Must
be Side by Side to connect
to both L1 & L2 120v legs
i.e. Lights, Heater
Black & Blue Wires = Circuit 1
Red & Orange Wires = Circuit 2
Installation of ELK-9100 at the Load
Controlling One 240 VAC Circuit Load
ELK-9100
LINE SIGNAL
CIRCUIT1
CIRCUIT2
PUSH ON
PUSH OFF
ELK-9100
240V - 30A
HEAVY DUTY
ULTRAMATE
Electrical
Junction
Box
GND
TO
LOAD
BL
UE
RED
FROM
BREAKER
PANEL
L1
L2
LOAD
After disconnecting power, mount the 9100 and a 4" electrical
junction box near the load. (water heater, motor, etc.)
Disconnect the existing wiring from the load and route it into
the junction box. Add wiring from the junction box to the load
and wire according to the diagram.
Note: The ELK-9100 cannot be powered
from GFCI Ground Fault Breakers.
However, GFCI Breakers can be utilized
on the output (load) side of the ELK-9100
Note: The ELK-9100 cannot be
powered from GFCI Ground Fault
Breakers. However, GFCI
Breakers can be utilized on the
output (load) side of the ELK-9100
Electrical Circuit
Breaker Panel
Figure 1
Figure 2
4"
Electrical
Junction
Box
(or other load)
(i.e. Water Heater)
This is the preferred method when the circuit breaker panel is flush
mounted, not accessible, or far away from the load. It requires a
separate 4" electrical junction and wire connectors for safely
completing the installation.
Existing Wiring
to the Load
Remote from Load
Circuit 1
120 VAC Device
i.e. Lights, Heater
BLACK
RED
BLUE
ORANGE
NEUTRAL
GROUND
Not
Suitable
for Wet
Locations
Not
Suitable
for Wet
Locations
4