background image

M1 Cross Platform Controllers - User Guide

Page 13

Chime Mode, Turning On and Off

Chime is a function which can provide an audible alert whenever certain
doors, windows, or other selected zones are violated.  The ideal application is
for annunciating whenever someone enters or leaves the premises through a
normal doorway.  However, it can also be used to annunciate abnormal
access to and restricted areas.

NOTE: The M1 control has four selections for Chime: Tone, Voice, Tone/Voice,
and Off.  The M1EZ8 control has only two selections for Chime: Tone or off.

When the Chime mode is On, the Chime key will be lighted.

To turn the Chime mode Off:

1.

Press the Chime key one time.

If the Chime mode is off, the Chime key will be dark (not-lighted).

To turn the Chime mode On:

1.

Press the Chime key one time to select the Chime Tone mode.

2

. Pressing the Chime key a second time within ~30 seconds of the

last press will select the Chime Voice mode.

3.

Pressing the Chime key a third time within ~30 seconds of the last
press will select the Chime Tone/Voice mode.

4.

Pressing the Chime key a fourth time within ~30 seconds of the last
press will once again turn the Chime mode Off.

Only your installer has be ability to program which doors, windows,
etc. (zones) will be included in the Chime mode.

Summary of Contents for Cross Platform Control ELK-M1KP

Page 1: ...USER GUIDE Cross Platform Control This Guide covers the operation of the M1 and M1EZ8 Controller models TM L519 Rev G 05 07...

Page 2: ...FOLLOWING The level of security obtained is directly related to two major factors 1 The quantity quality and placement of sensors attached to this system 2 The knowledge and operating skills that you...

Page 3: ...he System 11 Alarm Acknowledgments 12 Troubles 12 Chime Mode Turning On and Off 13 Keypad Menus 14 Menu 1 View Control Automation Functions 14 Menu 2 Reset Smoke Detectors 16 Menu 3 Walk Test Area zon...

Page 4: ...ll be heard when certain zone s are opened If OFF the chime mode is off Bypass Key Will be lighted anytime one or more zones have been excluded or bypassed If OFF no zones are bypassed Key This key se...

Page 5: ...dible police holdup alarm and notifies a central monitoring center if monitoring has been purchased It is generally programmed as double press or press and hold for 2 seconds Medical If enabled this k...

Page 6: ...______ Burglary Alarm Audible Cutoff Timer in minutes _______ Fire Alarm Audible Cutoff Timer in minutes _______ User Code Digits 4 digits ____ or 6 digits ____ F1 Key Function _______________________...

Page 7: ...y name and number If a zone is programmed as bypassable you may bypass it permanently exclude it for the immediate arming cycle by pressing the Bypass key zone number the Bypass key again The display...

Page 8: ...ming in the Vacation Mode Vacation mode is a second level of Away mode It can be used to activate energy saving automation features when the building will not be occupied for an extended period of tim...

Page 9: ...tional If this feature was enabled by your installer it will allow arming in either the Away or Stay modes without having to enter your user code For security reasons however a user code is always req...

Page 10: ...ess the Bypass key again 4 The Bypass light will light up if the bypass is accepted However if the zone is non bypassable an error tone will be heard Quick Bypassing of Violated Zones Optional The Qui...

Page 11: ...larm 1 Proceed directly to the keypad 2 The display will show the alarm type and first zone that tripped 3 Enter your user code 4 The entry delay tone should stop 5 When the Armed light turns off the...

Page 12: ...are many different types of trouble conditions that can be annunciated by the system including the following Trouble Conditions AC Power Failure Low Backup Battery Telephone Line Fault Fire Alarm Trou...

Page 13: ...ime Tone or off When the Chime mode is On the Chime key will be lighted To turn the Chime mode Off 1 Press the Chime key one time If the Chime mode is off the Chime key will be dark not lighted To tur...

Page 14: ...he first of 6 sub menus 1 TASKS will be displayed Each press of the UP arrow key will scroll through the other sub menus 4 When the desired menu displays press the RIGHT arrow to select 1 TASKS Tasks...

Page 15: ...control individual outputs An output may be a relay used to signal or switch a device On or Off Outputs are not necessarily a physical form Outputs must first be assigned and programmed by the instal...

Page 16: ...rature is displayed Press the key to exit NOTE To reduce scroll time the keypad only displays the entities Tasks Lights Outputs Temperature Sensors Keypads and Thermo stats which are installed program...

Page 17: ...splay 6 Continue walk testing until each zone is tested as indicated by the top left hand number being the same as the number to it s right 7 When finished press the key to exit back to the main displ...

Page 18: ...to a specific user 5 The keypad will display 001 Sel Chg name of User 6 To change the code press the RIGHT arrow and enter the new code digits Codes are either 4 or 6 digits in length depending on how...

Page 19: ...enu 8 System Settings Requires a Master Level User Code With the exception of Set Sys Clock this menu is primarily used by a service technician It has 8 sub menus 81 SET SYS CLOCK 24 hr format Enter a...

Page 20: ...ATION 85 CONNECT RP REMOTE PROGRAM Do Not Use except under guidance of the installation company There are two options Option 1 Pickup on Existing Call The system picks up the phone line and take over...

Page 21: ...med number of rings the control should answer with four short beeps If an answering machine picks up wait for the message to quit and proceed as follows 2 Press to alert the control The control will a...

Page 22: ...If the dialer is in use such as during an alarm message report then no dialtone will be heard and the offhook sequence will be ignored The best thing to do at that point is to try again a later when t...

Page 23: ...instructions on resetting Smoke Detectors Acknowledge Reset an Alarm After a fire alarm is silenced the display will continue to show Fire Alarm until the detectors are reset and the alarm has been ac...

Page 24: ...ish a meeting place outside where your family is to report Once you have evacuated the house do not return to a burning house 7 Advise the local fire authority that you have installed a fire alarm sys...

Page 25: ...crew securing the transformer to the wall 2 The keypad will display AC Trouble after a programmed time delay 3 Activate the system using steps 1 to 7 listed above NOTE Plug the AC transformer into the...

Page 26: ...e no user serviceable components in this product All necessary repairs must be made by the manufacturer Other repair methods may invalidate the FCC registration on this product This equipment cannot b...

Page 27: ...g Station Location where alarm reports are transmitted Chime An audible alert used to indicate when a zone is violated The alert can be a tone voice or both Zones are selectable Duress Code A special...

Page 28: ...www elkproducts com Printed in USA...

Reviews: