INSTALLATION OF THE HEATER
17
•
The appliance must be installed on a wall in a stable horizontal position and at least 1.8 meters above the
floor! Observe the minimum distances the heater from the ceiling and surrounding wall - the minimum distance
must be observed according to figure no. 2
•
Do not install the heater vertically or in inclined position! Do not install on to ceilings!
•
•
The minimum distance of objects from the heater should be at least 1 meter
.
Wall installation:
•
In order to insert the wall studs, drill two holes with appropriate size into the wall, at least 180 cm from the floor,
along a horizontal line and 315 mm from each other.
•
Insert the studs into the holes then screw the enclosed screws into the studs so that the screw heads extend
approx. 10 - 15 mm from the wall surface.
•
Hang the unit’s rear panel onto the screw heads at the holes, move it to the right then let it down till stop.
•
The heater is installed. Make sure that the heater is hanging securely on the wall!
OPERATION
•
Before connecting and switching on the heater, make sure that the socket has a fuse at least 10 A.
•
The device is operated with the supplied remote control.
•
Insert 2 pcs AAA size (1,5V) batteries to the remote controller (batteries are not included). Take care of the right
polarity! This completes the setup of the appliance
.
•
Plug the unit’s AC power cable into a grounded wall outlet ~ 220-240 V, 50/60 Hz.
•
After connecting the unit to the power network it will beep short and goes into standby mode. The network
connection light lights up
~
and the temperature display will show the current temperature in °C
.
Operation of the device:
•
You can turn on and off the appliance with the
On/Off
button on the remote controller.
•
After the
On / Off
button is pressed for the first time, the heater switches on and starts to operate in fan mode
- it will only blow the cold air. At the same time, the fan indicator will light .
•
By pressing the
Heating
button selects the heating levels I and II or the fan without heating.
- press Heating button one time, heating with half power output of 1000 W will start - indicator light
I
illuminates.
- press Heating button twice, heating with full power output of 2000 W will start - indicator light
II
illuminates
.
- pressing the Heating button again turns the heating off and the heater will operate again in fan mode.
• The
Swing
button activates the oscillation of the hot air flow blades and can also be stopped in the desired
position by pressing the Swing button again. When the swing function is on, the light is on.
•
Use the
+ / -
buttons to set a higher or lower desired temperature in the range of 18 - 45 °C, which the
heater displays on the display with blinking numbers.
•
Continuous temperature display means its current value. If the temperature drops below the set level, the
thermostat switches on the I or II heating stage. As soon as the temperature is raised to the set value, the heater
are turned off, but the fan function remains in operation. The oscillating blade remains in action according to
the Swing setting. The Cancel button does not affect this device.
ELECTRICAL CONNECTION
Rated voltage: ~ 230 V / 50 Hz
Fuse: 10 A
Wiring and connection must be performed according to valid regulations and standards. Part of the heater is
movable power cord with plug for 230 V. Connect the power cord into a socket with protective contact. Do not
place the heater directly under or above the socket outlet.
EN
Operating instructions
Summary of Contents for EWH 200
Page 2: ...SK 2...