14
PROGRAMMING
TRIGGER MODE: HIGH TEMPERATURE
In this mode, pressing the up or down button sets
the high temperature trigger. The fan will activate if
the probe’s reading meets or exceeds this trigger.
It will gradually ramp up until it reaches the ON
Mode’s setting. If the probe’s reading falls below
your trigger, the fan will turn off. We recommend
turning this trigger OFF when not in use during set
up by holding the up and down buttons together.
You may set this trigger below the low temperature
trigger to create a range where the fan is active.
TRIGGER MODE: LOW TEMPERATURE
In this mode, pressing the up or down button sets
the low temperature trigger. The fan will activate if
the probe’s reading meets or falls below this trigger.
It will gradually ramp up until it reaches the ON
Mode’s setting. If the probe’s reading rises above
your trigger, the fan will turn off. We recommend
turning this trigger OFF when not in use during set
up by holding the up and down buttons together.
You may set this trigger above the high temperature
trigger to create a range where the fan is active.
Note that this trigger can activate as
long as you are in AUTO Mode, even
if you are viewing a different trigger
within AUTO Mode.
Note that this trigger can activate as
long as you are in AUTO Mode, even
if you are viewing a different trigger
within AUTO Mode.