background image

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 
satisfactory operation of this product. Please retain these instructions for future reference.

Warning

This is a Class 1 product and must be earthed.
Please read these instructions carefully before commencing any work.
Install in accordance with IEE Wiring regulations and current Building Regulations.
To prevent electrocution switch off at mains supply before installing or maintaining this fitting. Ensure other persons 
cannot  restore the electrical supply without your knowledge. If you are in any doubt, please consult a qualified 
electrician.
This light fitting should be connected to a circuit with a 30mA RCD fitted.
If replacing an existing fitting, make a careful note of the connections.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. 
Check with your local authority or retailer for recycling advice.
This light fitting contains non-replaceable parts and cannot be serviced.
If damage occurs the part should be discarded.
This product is rated at IP65.
This product is not suitable for location in or near a marine environment.

Specification

Voltage: 

240V 50Hz a.c.

Lamp: 

6W LED module

Lumens: 470lm
IP rating: 

65

• 

You have correctly identified 
the wires.

• 

The connections are tight.

• 

No loose strands have been 
left out of the connection 
block.

If not fitting to a plug, then the product must be wired to a IP65 rated terminal block.

Wiring - Terminal Block

Check that...

Layout

•  Decide on the position of the luminaire. Depending on the location, an approved outdoor rated plug and socket 

may be required. Alternatively an approved outdoor rated external terminal block may be used.

•  Avoid locating any cables in positions that would cause a hazard. Position cables and connector block away 

from areas where they may be at risk from being cut, trapped or damaged.

•  Cables that are to be in walls and concealed underground must be protected using suitable conduit or plastic 

trunking.

•  Ensure that the ground is suitable for pushing the spike into, and can support the luminaire. Do not install in 

very wet or boggy areas.

Wiring - Plug

•  The appliance must be connected to a 240 volts AC 

supply.

•  The appliance can be fitted to a rewireable 3 pin 

plug fitted with a 3 amp fuse. Should the fuse 
require replacement, it must be replaced with a fuse 
rated at 3 amp and approved to BS1362.

• The wires in the mains lead on this appliance are 

coloured in accordance with the following code:

    Blue – Neutral
    Green / Yellow - Earth
    Brown – Live

Commissioning

•  Ensure that the ground is suitable for pushing the spike into, and can support the luminaire. Do not install in very 

wet or boggy areas. Connect the stem to the spike by screwing the stem into the spike and secure to the light 
fitting by tightening the screw in the bracket into the stem. Push the assembled product into the ground.

•  Replace fuse or circuit breaker and switch on. Your light is now ready for use. 