Elite 11000EPH90 Installation And User Manual Download Page 3

PUMP STRAINER BASKET 

This unit, sometimes referred to as the “Hair and Lint Pot”, is the unit in front of the volute. Inside 

the chamber is the basket which must be kept clean of leaves and debris at all times. View basket 
through the “See Through Lid” to inspect for leaves and debris. Regardless of the length of time 

between filter cleaning, it is most important to visually inspect the hair and lint pot basket at least 
once a week. A dirty basket will reduce the efficiency of the filter and heater and also put an 

abnormal stress on the pump motor which would result in a costly repair bill. 
 

WARNING

: DO NOT 

open the strainer pot if pump fails to prime or if pump has been 

operating without water in the strainer pot. Pumps operated in these circumstances may 

experience a build up of vapor pressure and may contain scalding hot water. Opening the 

pump may cause serious personal injury. In order to avoid the possibility of personal 

injury, make sure the suction and discharge valves are open and strainer pot temperature is 

cool to touch, then with extreme caution. 

CAUTION

To prevent damage to the pump and filter and for proper operation of the 

system, clean pump strainer and skimmer baskets regularly. 

 

WARNING

: THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN 

ANY PART OF THE CIRCULATION SYSTEM (e.g. LOCK RING, PUMP, 

FILTER, VALVES, ETC) IS SERVICED, AIR CAN ENTER THE SYSTEM AND 

BECOME PRESSURIZED.  PRESSURIZED AIR CAN CAUSE THE LID TO 

BLOW OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR 

PROPERTY  DAMAGE. TO AVOID THIS POTENTIAL HAZARD, FOLLOW 

THESE INSTRUCTIONS. 

 
 
 
 

1.

 

Turn off motor. 

2.

 

Relieve pressure in the system. 

3.

 

Turn the lid in a counter-clockwise direction until it 

stops. 

4.

 

Lift lid and remove basket. 

5.

 

Put the debris from the basket into the trash and rinse 
out the basket. If the basket is cracked, it should be 

replaced. 

6.

 

Replace the basket and fill the pump pot and volute up to 

the inlet port with water. 

7.

 

Clean the cover, O-ring and sealing surface of the pump 

pot. Grease the O-ring with Teflon or silicone. 

8.

 

Reinstall the lid. 

9.

 

Make sure the lid O-ring is properly placed. Seat the lid 
then turn clockwise until hand tight (

DO NOT 

over 

tighten with tools) 

 

Summary of Contents for 11000EPH90

Page 1: ...Elite Primer Pro High Head Series External Pond Pump 6000EPH75 7500EPH75 8200EPH82 9200EPH82 11000EPH90 13000EPH110 Installation and User s Guide ...

Page 2: ...age 230v or 115v If they do not match the motor will burn up 3 Choose the correct wire size When in doubt use a heavier gauge larger diameter wire Heavier gauge will allow the motor to run cooler and more efficient 4 Cut wires to the appropriate length so they don t overlap or touch when connected to the terminal board 5 Make sure all electrical connections are clean and tight 6 Permanently ground...

Page 3: ...alves are open and strainer pot temperature is cool to touch then with extreme caution CAUTION To prevent damage to the pump and filter and for proper operation of the system clean pump strainer and skimmer baskets regularly WARNING THIS FILTER OPERATES UNDER HIGH PRESSURE WHEN ANY PART OF THE CIRCULATION SYSTEM e g LOCK RING PUMP FILTER VALVES ETC IS SERVICED AIR CAN ENTER THE SYSTEM AND BECOME P...

Page 4: ...ump basket 3 Cover the motor to protect it from severe rain snow and ice 4 Do not wrap the motor in plastic It will cause condensation and rust on the inside of the motor CARE OF ELECTRIC MOTOR PROTECT FROM HEAT Shade the motor from the sun Any enclosure must be well ventilated to prevent overheating Provide ample cross ventilation PROTECT AGAINST DIRT Protect from any foreign matter or splashing ...

Page 5: ...to avoid the possibility of personal injury make sure the suction and discharge valves are open and strainer pot temperature is cool to touch then with extreme caution PUMP DISASSEMBLY CAUTION Be sure not to scratch or mar the polished seal faces Seal will leak if faces are damaged All moving parts are located in rear sub assembly of this pump Tools required 1 2 inch open end wrench 9 16 inch open...

Page 6: ... to clean the seal Press the seal into the impeller with your thumbs and wipe off the ceramic and carbon faces with a clean cloth 3 Remount the seal plate to the motor 4 Screw the impeller onto the motor shaft 5 Remount the diffuser onto the seal plate 6 Grease the diffuser O ring 7 Assemble the motor sub assembly to the strainer pot pump body DO NOT tighten down any of the bolts until all 6 bolts...

Page 7: ...prime and causing the pump to run dry resulting in a damaged seal If the pump is installed below the water level of the water garden close return and suction lines prior to opening hair and lint pot on pump Make sure to re open valves prior to operating The pump strainer pot must be filled with water before the pump is initially started Follow these steps to prime the pump For 2 speed pumps Pump s...

Page 8: ...ve glands on all suction gate valves b Secure lid on pump strainer pot and make sure lid gasket is in place c Check water level to make sure skimmer is not drawing air 2 Pump will not prime not enough water Remedy a Make sure suction lines pump strainer and pump volute are full of water b Make sure valve on suction line is working and open some systems do not have valves c Check water level to mak...

Page 9: ...ved complete the following steps i Remove left hand threaded bolt and gasket ii Remove clean and reinstall impeller iii Reinstall left hand threaded bolt and gasket f Reinstall the diffuser and diffuser O ring g Reinstall motor and seal plate into volute h Tighten bolts securely 3 Pump strainer clogged Remedy a Clean suction trap ...