![Elisra MW-CBDA SERIES 10W-80-A Installation And Operating Instructions Manual Download Page 9](http://html.mh-extra.com/html/elisra/mw-cbda-series-10w-80-a/mw-cbda-series-10w-80-a_installation-and-operating-instructions-manual_2389386009.webp)
Dekolink Wireless Ltd.;16 Bazel St.Qiryat-Arieh Petah-Tikva Israel, 49510
Tel- 972-3-9180-180; Fax-972-3-
190
-
9180
;
:
TRICAL SPECIFICATIONS
ELEC
Frequency Range (MHz)
SEE TABLE
Passband Gain @Min attenuation
80 dB nominal
Passband Ripple
±
1.5 dB typical
Manual Attenuation Range
0 to 30 dB in 2 dB step
Noise Figure
6.0 dB max
Impedance level
50 ohms
V.S.W.R In/Out
1.5 : 1 max
AGC Selection
By ON/OFF Switch
AGC Attenuation Range
25 dB typical
AGC LED Indication
LED turn ON when power reaches AGC Set
Power Level. (both at On and Off positions).
AGC Factory Power Preset
Up link: +24 dBm nom.
Down link: +30 dBm nom.
Amplifier Power Output
@1 dB Compression
Up Link : 1 Watts
Down Link : 10 Watts
3rd Order output Intercept point
Up Link : +45 dBm typical
Down Link :+50 dBm typical
Power Supply
110/220V AC, 50-60 Hz /1A
System Frequency Range
SYSTEM TYPE
MODEL No
DOWN-
LINK
UP-
LINK
E-SMR (iDEN)
MW-CBDA-ESMR-10W80A
851-866
806-821
SMR 800-Public Safety
MW-CBDA-SMR-10W80A-PS8
851-869
806-824
SMR - 900 MHz
MW-CBDA-SMR-10W80A-PS9
935-941
896-902
GSM
MW-CBDA-GSM-10W80A
935-960
890-915
TDMA Band B
MW-CBDA-CELLB-10W80A
880-894
835-849
CDMA/TDMA/N-AMPS
MW-CBDA-AB-10W80A
870-894
825-849
;
Web site-
www.dekolink.com
r
ev 5 11/
02
page 9 of 12