background image

Error/Message

Suggestions and Checks

“Could not connect to 
the shower”

If a serial number is displayed, tap on 

Try Again

. If no serial 

number displayed tap on 

Cancel

 and then go through the 

process again, ensuring that the below suggestions are followed.

“Network unavailable”
            Or
Wifi drops when 
connecting to the 
QSVC

Note: The setup process requires good signal strength between 
your phone and the SmartValve (not the shower controller).
Close any running apps on the phone before commencing.
Turn off the mobile data connection in the phone’s settings.
Select "Keep WiFi Connection with No Internet" where and when 
promoted.
Ensure that your phone / smart device is connected to the home 
Wifi network (try running a program or app that requires Wifi 
connection).
Close and re-open the ShowerMe app.
In the app journey ensure that QSVC is being selected and that the 
password SmartShower is entered correctly- you do not have to wait 
for connection confirmation, once QSVC has been selected wait a 
few seconds and then return to the ShowerMe app.
Ensure that you are keying your SSID (home Wifi) and password 
correctly.

“The operation could 
not be completed” 
(when trying to start 
shower)

Ensure your Wifi is working.
Check that the shower operates using the main controller.
If the shower does not work via the main controller, check there 
is power to the SmartValve (possibly tripped fuse / circuit or 
accidentally switched off).
Turn power off to the SmartValve for a few minutes and then 
reinstate.
Close any other running apps .

Primary Outlet Selection
(Divert Models only)

The primary outlet is set up during installation by utilising the 
outlet switch on the diverter (see Diverter Outlet section in the 
Smart Shower Installation Guide).
The switch position will determine the primary outlet for the main 
controller and wired remote. Smart speakers (e.g. Alexa / Hey 
Google) will always start the outlet which was last used. 
When using the ShowerMe App: Outlet A is always the Primary 
outlet regardless of the diverter switch position. 

Locating the shower 
serial number

From the Home Tab, select the SHOWERS tab, then choose the 
shower to display the serial number.

App Troubleshooting

For further assistance utilise the Instabug reporting platform - see details on page 11.

Symptom

Possible cause

Action

Controller 

unresponsive - 

No Lights / Blank

Power supply turned off 

to SmartValve

Check power supply is turned on - Green power 

light should be illuminated on the SmartValve.

Loss of 

communications

Check data cable connections are making 

good contact and are fully inserted and that 

there is no visible damage.
Check that the wiring schematics are as per 

installation instructions in the Smart Shower 

Installation Guide.

Pump noisy and  

low / no flow

Air lock (for Gravity fed 

systems only)

For models utilising an adjustable head kit; 

disconnect the handset from the hose, see Head 

section on page 8, lower the hose into the shower 

tray or bath. Set the temperature to fully cold 

and then start the shower. As the water starts to 

flow and increase in volume gradually turn up 

the temperature. If the flow starts to splutter, stop 

moving the temperature control until the flow 

again stabilises, then continue to move the dial 

towards the hottest setting. 

Restriction in the 

waterway

Check for debris in the inlet filters of the 

SmartValve, diverter and Fixed Head connection 

washer. Must be conducted by a qualified 

person. NOTE: The water supplies MUST be 

isolated when checking the inlet filters.

Blocked or kinked hose 

liner

Where a flexible hose is fitted, unscrew the 

shower hose from the outlet connection and 

turn the shower on. 

Boost button 

does not 

increase flow

Combination boiler 

output does not meet 

the flow demand

Check with boiler manufacturer for 

specification details. 

SmartValve

is set to ECO mode

Refer to Setting Water System Mode section in 

the Smart Shower Installation Guide. 

Seasonal conditions

During the cooler months the mains water 

temperature drops and this will reduce the 

performance of combination boilers. Check with 

your boiler manufacturer for details.

Low / no flow

Seasonal conditions

See above point. 

Incorrect SmartValve

fitted

If water supplies are gravity fed, the PUMPED 

SmartValve must be used (unless a separate 

stand alone pump is being utilised). Refer to 

the Smart Shower Installation Guide.

Shower Troubleshooting

Refer to page 16 for App Troubleshooting.

16

17

Summary of Contents for incite

Page 1: ...User Guide incite...

Page 2: ...ser maintenance shall not be made by children without supervision For further information regarding the installation of your product refer to the Smart Shower Installation Guide Declaration of Conform...

Page 3: ...op button on the controller to turn the shower off BOOST TEMPERATURE START STOP Adjust before or during shower Increase flow rate during shower As a safety feature the SmartValve has a maximum run tim...

Page 4: ...without any outlets flowing enable Setup mode by first turning the temperature dial to full cold Press and hold both buttons together for 5 seconds The LEDs will flash twice quickly and once slowly to...

Page 5: ...bove recommendation applies to both adjustable and fixed shower heads Rotate the spray plate lever clockwise or anticlockwise to select the desired spray pattern To select the preferred height for the...

Page 6: ...e manufacturer s instructions substances that are not suitable for plastics and electroplated surfaces must not be used Changing water system If switching from a gravity fed water system to a mains pr...

Page 7: ...6 7 4 5 1 2 3 Connecting to the App THE STEP BY STEP INSTRUCTION ON CONNECTING THE SHOWER Connecting to the App THE STEP BY STEP INSTRUCTION ON CONNECTING THE SHOWER 12 13...

Page 8: ...newly set duration overriding the default maximum run time Note the water flow will stop at the end of the timer The ShowerMe app gives you the capability to operate your product remotely using your...

Page 9: ...tab then choose the shower to display the serial number App Troubleshooting For further assistance utilise the Instabug reporting platform see details on page 11 Symptom Possible cause Action Controll...

Page 10: ...ck if another outlet in the property is being used at the same time Check that the hot water temperature is stable at another high flowing outlet e g bath hot tap run at maximum flow rate additionally...

Page 11: ...res servicing Check the user guide for the hot water system to verify symptoms and where required arrange for servicing Flow shuts off by itself Maximum run time exceeded or end of duration reached in...

Page 12: ...our Customer Service team on 01959 560010 Use Live Chat at elisabathrooms com Or email us at enquiries elisabathrooms com Instabug reporting platform for the ShowerMe app Accessed in the app by Shakin...

Page 13: ...ange or modify the product specifications without prior warning Registered Trademark Aqualisa Products Limited Q5598 Part No 705734 Issue 01 Nov 21 The Flyers Way Westerham Kent TN16 1DE Customer Serv...

Reviews: