background image

Hardware Description

 

3           

 

 

               

Manual Documentation Number EIR405-T – 0109m 

www.bb-elec.com

 

 

www.bb-europe.com

 

Hardware Description 

 

 
 

Front Panel   

 

The Front Panel view of the EIR405-T is shown below. 

 

 

 

 
 
 
 
 
 
 

Summary of Contents for EIR405-T

Page 1: ...i Manual Documentation Number EIR405 T 0109m www bb elec com www bb europe com E EI IR R4 40 05 5 T T U Us se er r M Ma an nu ua al l ...

Page 2: ...Website www bb europe com 2008 B B Electronics Mfg Co Inc No part of this publication may be reproduced or transmitted in any form or by any means electronic or mechanical including photography recording or any information storage and retrieval system without written consent Information in this manual is subject to change without notice and does not represent a commitment on the part of B B Electr...

Page 3: ...ng the Power Inputs 4 Wiring the Fault Alarm Contact 5 LED Indicators 6 Ports 6 Cabling 8 3 Mounting Installation 11 DIN Rail Mounting 11 Wall Mount Plate Mounting 13 4 Hardware Installation 14 Installation Steps 14 5 Troubleshooting 16 6 Technical Specification 17 iii Manual Documentation Number EIR405 T 0109m www bb elec com www bb europe com ...

Page 4: ...ts If the power fails the switch will automatically switch to the secondary power input Also if the power goes out the corresponding P1 or P2 LED will go out and the Fault LED will light The contacts for the alarm output will also open Flexible Mounting The EIR405 T can be DIN or Panel mounted The compact design is suitable for space constrained environment such as a small cabinet Advanced Protect...

Page 5: ...ps Ethernet ports Supports full half duplex flow control Supports auto negotiation 10 100 1000 Supports MDI MDI X auto crossover Supports Jumbo Frame of 9Kbytes Supports surge EFT protection 3 000 VDC for power input Supports 6 000 VDC Ethernet ESD protection Supports redundant 12 to 48 VDC power inputs Provides flexible mounting DIN rail or Panel Mounting Supports operating temperatures from 40 t...

Page 6: ...Hardware Description 3 Manual Documentation Number EIR405 T 0109m www bb elec com www bb europe com Hardware Description Front Panel The Front Panel view of the EIR405 T is shown below ...

Page 7: ...ed with one terminal block connector that consists of two 12 to 48 VDC power inputs and the fault alarm output Wiring the Power Inputs Follow the steps below to insert the power wires 1 Insert the positive and negative wires into the V and V contacts on the terminal block connector 2 Tighten the wire clamp screws to prevent the wires from becoming loose ...

Page 8: ...t Alarm Contact The fault alarm contact is in the middle of terminal block connector as the picture shows below If one of the power sources fails a fault will be detected causing the circuit to open Note The wire gauge for the terminal block should be 12 to 24 AWG Insert the wires into the fault alarm contact No 3 4 ...

Page 9: ...tive Fault Red Off Power inputs 1 and 2 are both active or no power is present On Connected to network Flashing Networking is active Ports 1 to 5 Upper LED Green Off Not connected to network On Connected to network at speed of 1000Mbps Ports 1 to 5 Lower LED Green Off Not connected to 1000Mbps network Ports RJ 45 ports The RJ 45 ports auto sense for 10 100 or 1000 Mbps devices connections The auto...

Page 10: ... network connections to PCs or servers or to other switches or hubs In straight through cables pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD 2 Receive Data minus RD Tr...

Page 11: ...europe com Cross Over Cable Schematic Cabling Use unshielded twisted pair UTP or shielded twisted pair STP cable 10Mbps Use category 3 4 5 or greater cable 100Mbps Use category 5 or greater 1000Mbps Use category 5e or greater cable Cable distances should be less than 100 meters 328 ft long ...

Page 12: ...Hardware Description 9 Manual Documentation Number EIR405 T 0109m www bb elec com www bb europe com ...

Page 13: ...Hardware Description 10 Manual Documentation Number EIR405 T 0109m www bb elec com www bb europe com ...

Page 14: ...comes screwed on to the switch from the factory If the DIN rail clip is not screwed on the switch please see the following figure to re attach the DIN Rail clip Then follow the steps below to hang the switch onto a DIN rail 1 Use the screws to screw the DIN rail clip onto the switch 2 To remove the DIN rail clip reverse step 1 Rear Panel of the switch DIN Rail ...

Page 15: ...www bb elec com www bb europe com 3 First insert the top of DIN rail clip onto the piece DIN rail track 4 Then lightly push the bottom of the switch so it can snap the rest of the way onto the DIN rail track 5 Check that the switch is held tightly to the DIN rail track ...

Page 16: ...so that the switch can now be carefully lifted off the DIN rail track Wall or Panel Mount Plate Mounting Follow the steps below to mount the switch with the wall mount plates 1 Remove the DIN rail clip from the switch loosen the screws to remove the DIN rail clip 2 Place the wall mount plate on the side panels of the switch 3 Use the screws to screw the wall mount plate onto the switch 4 Use the h...

Page 17: ...ical switch installation for the EIR405 T Installation Steps 1 Unpack the switch 2 Check that the DIN rail is screwed onto the switch If the DIN rail clip is not screwed onto the switch Please refer to DIN Rail Mounting section for DIN Rail installation If you want to wall or panel mount the switch then please refer to Wall or Panel Mount Plate Mounting ...

Page 18: ...ng of LED lights 4 Prepare the twisted pair Ethernet cable for connection 5 Insert one side of cable into one of the switches Ethernet ports and the other side of the cable to the network device you want connected ex switch PC or Server The port LED on the Industrial switch will light up when the cable is connected to the network device Please refer to the LED Indicators section for LED light mean...

Page 19: ... the LED indicators on the front panel of the switch The LED s can help describes common problems you may encounter and where you may find possible solutions to assist in identifying problems If the power indicators do not light on when power is applied you may have a problem with the power supply Check for loose power connections power losses or surges at the power outlet If the switch LED s repr...

Page 20: ...Up to 1000 Mbps Broadcast Storm Rate Limit 7 926pps default Interface Connectors 5 x RJ 45 5 port 10 100 1000TX 6 pin removable screw terminal power input fault relay output LED Indicators Unit P1 P2 Fault Ethernet port Link Active 100Mbps Link 1000Mbps Power Power Consumption 4 6 W Power Input 2 x Unregulated 12 to 48 VDC Fault Output 1 Relay Output Mechanism Dimensions WxDxH 30 x 95 x 140 mm 1 2...

Page 21: ...rature 40 to 75o C 40 to 167o F Operating Humidity 5 to 95 non condensing Storage Temperature 40 to 85o C 40 to 185o F Certifications Safety UL cUL CE EN60950 1 EMC FCC Class A CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 CE EN61000 4 11 CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibrati...

Reviews: