9
The flash / modelling lamp power is displayed in f-stop compatible formats from 2.0 – 6.0 for
D-Lite it 4 / 400 ws
. The flash power difference from (e.g.) 5.0 – 6.0 is 1f-stop.
The power range is 5 f-stops, variable in 1/10th intervals. During charging or discharging, the
display «flashes». In case of overheating or malfunction, the display shows “E” for error followed
by the error code number.
Display
2.0
3.0
4.0
5.0
6.0
Joules / Ws
25
50
100
200
400
Note: The «D-Lite 2 it - D-Lite 4 it» units have an integrated discharge system, protected by a
thermal switch. To avoid overheating, discharge manually with the «test» button if you want to
decrease the power for more than 2f-stops.
Digital multi-display
English
Sychronisation socket
Open flash «test»
The standard photocell can be remotely triggered by another flash unit!
The D-Lite it photocell is specially designed to work in studio light conditions
Direct light or other strong light sources may reduce the sensitivity of the cell.
Eye-Cell – advanced photocell sensor
Having pressed the touch pad to release a flash, the green «READY» light
will appear again once the unit is recharged. If the green light does not
appear the charge system could be defective.
Please contact an authorized Elinchrom service centre.
Test and Ready (4)
5
Sync
Standard socket with 3.5 mm mini-jack (5).
N.B. Do not link ELINCHROM units by cable to other manufacturers sync. outlets.
ELINCHROM uses low voltage (5 V) for security reasons.