E-70-Ö DIGITAL CONTROLLER USER MANUAL

5. CONNECTION DIAGRAM

Before operating the controller, ensure that the controller
is correctly configured. Incorrect configuration could
result in damage to the process being controlled.

m

The terminals 01 to 07 are electrically live. While the
instrument is powered, never touch to these terminals.

m

The labels on the sides of the controller identify the ordering
code (Type), serial number and wiring connections.

Connection diagram is given below.

Manufacturer / Technical Support:

Elimko Co. Ltd. 8. cadde 68. Sokak No:16 06510 Emek - ANKARA / TURKEY

Phone:+ 90 312 212 64 50 Fax:+ 90 312 212 41 43 www.elimko.com.tr e-mail:[email protected]

KY-70-1209-0-Ö

The front panel view of the E-70-Ö controller is given in
section. In normal operation, the four digit display displays the process
value and unit. The display of the controller displays between -19 and 99.
Out of this range or while the connection of the sensor is broken the
display will be shown as (

)

1. DESCRIPTION

--

6. OPERATION

The other parameters are configured in configuration mode.

q

In order to access the configuration mode,

and

buttons must be

pressed simultaneously.

C

D

q

Just after this operation,

message is displayed for one second

duration,

is displayed in the display. The security code must be

entered with

and

buttons in order to access the parameters.

COD

0

A

F

q

The entered security code must be correct, otherwise pressing
button will revert to normal operation.

D

q

The factory setting value of security code is “10”. The security code is
defined by

parameter; user can edit this parameter to define a new

security code. If the value of security code is forgotten, pressing

and

buttons simultaneously at least 10 seconds, makes possible to access

the parameters.

PAS

C

D

q

If the entered security code is correct, pressing

key will select the

first parameter.

C

q

While a parameter is selected, the parameter value is edited by

and

buttons.

Pressing

button will select the next parameter.

Pressing

button exist the configuration mode.

F

A

C

D

16

15

18

19

20

PT-100

02

21

17

04

03

01

06

07

3A

250

VAC

3A

250

VAC

05

24 V AC; 50-60Hz

24 V AC; 50-60Hz

RL1

3A

250

VAC

3A

250

VAC

RL2

7. EXPLANATION OF PARAMETERS

21 C

*

ASTL

0 C

*

SETL

2*C

Code ok.

Code wrong

COD

0

SETH

SFT

0*C

10*C

UNT

PAS

10

0

ASTH

10*C

COD

:

Security code is asked with this parameter. It can be
adjusted between -1999 and 9999.

SFT

:

Defines the shift value of the input. It can be adjusted
between -10°C and 10°C. The value of input that seen
on the display is the sum of measured value and
parameter.

SFT

UNT

:

Indicates the measuring unit of the input. It can be
adjusted as 0 (°C) or 1 (°F). If

parameter is changed,

,

,

,

, and

parameters should be

revised. Also the adjustment limits of set points are depend
on this parameter.

UNT

ASTL ASTH SETL SETH

SFT

PAS

:

Define the security code. Parameter can be adjusted
between -1999 and 9999.

ASTL

:

The low value of alarm set point. This parameter is
used for controlling Relay 2.

ASTH

:

The high value of alarm set point. This parameter is
used for controlling Relay 2.

SETL

:

The low value of control set point. This parameter is
used for controlling Relay 1.

SETH

:

The high value of control set point. This parameter is
used for controlling Relay 1.