2.4.3 DELAY TIME (Dly Time)

 

 

 Delay Time is only applicable for alarm point and irrelevant to status point

.  

 To set the desired Delay Time, key in the value (in 2 digits) which may be any 

form 00-99 seconds.

  

                    For Sensor Input 1         For Sensor Input 2  
 

.

 2.4.4 ALARM DURATION (Alm Dur)

 

 

 The duration of the sounder can be set by this command.

  

 When the sensors are armed, and there is an alarm, the sensor alarm output 

will activate.  This sensor output is normally connected to a sounder. 

If  Alarm  Duration  set  at  000,  the  sounder  will  continue  until  the  sensor  is 

disarmed 

If it is set to 300 seconds, then the sounder will continue for 300 seconds or 5 

minutes. 

If  the  input  sensor  is  still  not  disarmed  after  5  minutes,  the  sounder  will 

automatically be turned off. 

 

Set   Alm   Trg   Dly

 

Dlay 1 00 

Dlay 2 00

 

Summary of Contents for EL2305D

Page 1: ...EL2305D Access Control Panel User Guide Revision 1 1 20 0 EL2305D DOOR ACCESS CONTROLLER USER GUIDE Revision 1 1 20 ELID SDN BHD...

Page 2: ...CARD 5 1 3 TO PROGRAM THE ENGINEERING CARD 5 1 4 SETTING CARD TYPE 6 1 5 SETTING DISPLAY TYPE 7 1 6 SETTING EL2000 MODE 8 1 7 SETTING CONTINUOUS SWIPING 8 1 8 SETTING CARD SIZE 9 1 9 SETTING CLEAR SE...

Page 3: ...ision 1 1 20 2 2 6 TEST MENU 31 2 7 SAVE PARAMETER 36 2 8 CLEAR MEMORY 36 3 USER MENU 37 3 1 TEST MENU 39 3 2 CARD MENU 43 3 3 TRANSACTION MENU 49 3 4 DOOR MENU 51 3 5 SENSOR MENU 54 3 6 OUTPUT MENU 5...

Page 4: ...EL2305D Access Control Panel User Guide Revision 1 1 20 3 EL2305D DOOR ACCESS CONTROLLER Programming Keypad Layout...

Page 5: ...switch off and then switch back on the power supply Alternatively hold down keys A on the keypad and press the reset switch while power is on Release the keys 3 seconds after the power supply is switc...

Page 6: ...ER CARD Press A key in order to set the master card number You should key in 6 digit master card number followed by the key 1 3 TO PROGRAM THE ENGINEERING CARD Press B key in order to set the Engineer...

Page 7: ...y in 6 digit Engineering card number followed by the key 1 4 SETTING CARD TYPE Press C key to choose the type of reader and card format you wish to use You can change the card type by pressing D key r...

Page 8: ...D key to select DISPLAY TYPE command Code Details WIEG Wiegand Reader with 26 bit Wiegand format PROX Proximity Reader with ELID format EPRX Diester Reader with 48 bit Diester format FWIE Free Wiegand...

Page 9: ...ect EL2000 MODE command YES 6 outputs will emulate EL2000 being used for duress alarm door open alarm door shunt sensor alarm and sensor armed NO These output are General purpose Outputs that can be p...

Page 10: ...en the door is open NO The reading is disable until the door is closed 1 8 SETTING CARD SIZE Press C to select CARD SIZE command This command is for setting the data capture window of a Free Format It...

Page 11: ...umber MAX 40 000000 999999 Max bits to be taken for reading a card number LN 20 Max offset bits to read a card number OFS 20 1 9 SETTING CLEAR SECURITY Press D to select CLEAR SECURITY command YES If...

Page 12: ...e above set up you should press key from the main screen to exit The date time should appear on the LCD and the red light on the reader should begin to flash 1 10 BEFORE OPERATION A burn in operation...

Page 13: ...oor 2 Door 2 readers will not accept the master card Select ENGINEERING MENU and present the Engineering Card to Reader in Door 1 DOOR MENU Lock Release Time LR T Shunt On Time Shun T Door Sensor Dr S...

Page 14: ...tion Mode Delay Time Alarm Duration OUTPUT MENU Output Type Output Event Output Duration COMMUNICATION MENU Baud Rate Address Number Set Lan Apply Lan TEST MENU Test Keypad Test Reader Test Input Test...

Page 15: ...present the Master card to door 2 Door 2 readers will not accept the master card 2 Press key D and key in PIN 1 of the master card You can now select commands from either Engineering or User Menu To s...

Page 16: ...to 200 2 2 2SHUNT ACTIVATION TIME Shun T Each time the door is validly open as when a valid card is swiped the Door Shunt Output is activated The duration of activation may be set as a multiple of th...

Page 17: ...Ssor To select the type of Door Contact user wish to use either Door Open Contact Open select OPEN or Door Open Contact Closed select CLOSE 2 2 4PUSH BUTTON Push exit To allow or disallow the opening...

Page 18: ...own PIN number for each card PIN2 Pre defined PIN 2 2 6PIN ENTRY PIN ENT The PIN entry command allows you to set whether you wish to have the facility of opening the door by PIN number without card Us...

Page 19: ...enable or disable the buzzer sound for every valid card entry 2 2 8DOOR SENSOR DEBOUNCE Dr Ssor This command is applicable for certain locks which have built in door sensors Such built in sensors may...

Page 20: ...2 as either door 1 exit reader or door 2 entry reader 2 3 CARD MENU 2 3 1 DATABASE MODE DB Mode This command allows you to choose whether the controller should store name of each card or not If name i...

Page 21: ...transaction buffer then set the transaction database to extended 2 3 3 CARD SIZE Crd Size Refer 1 8 Setting Card size on page 10 2 3 4 DUAL CARD Dual Crd In dual card mode which is a high security mod...

Page 22: ...s NO The door will open as soon as the time zone set for automatic opening is activated 2 3 6 SPECIAL CARD MODE Spcl Crd CTYP Defined by Card Type Whether the card is recognize as special card or norm...

Page 23: ...7 Setting Continuous Swiping on page 9 2 4 SENSOR MENU 2 4 1SENSOR TYPE Ssr Typ Enter the no of door for the sensor Choose the signal comes from a device either Normally Closed Contact NC or Normally...

Page 24: ...as a Motion Detector however is normally in Non alarm State and when it goes to the other state it is in an abnormal condition and must cause the Sensor Alarm Output to be activated This would normal...

Page 25: ...opens You can do this by using the Interlock Inhibit input When programmed in the Inhibit mode each time the sensor input is activated the Reader will not open the door even when a valid card is swip...

Page 26: ...Alm Dur The duration of the sounder can be set by this command When the sensors are armed and there is an alarm the sensor alarm output will activate This sensor output is normally connected to a sou...

Page 27: ...r by timer EVENT MODE EVNT the output is also activated by an input event which may be any of the transaction codes recognized by the unit If you set to EL2000 OUTPUT EMULATION mode in INITIAL SET UP...

Page 28: ...t will cause the output to toggle ON OFF ON OFF etc o MULTIPLE MULT Each event will cause the output to send a succession of pulses each of 1 second duration in succession The number of pulses is prog...

Page 29: ...sor 4 Door Open Alarm I Status On Sensor 1 5 Pulse Door Open J Status Off Sensor 1 6 Invalid Customer Code K Door Closed 7 Invalid Time Zone L Keypad Locked 8 Anti Passback Alarm M Sensor Alarm Sensor...

Page 30: ...ND Out Dur This setting is to set the duration for which the output point is to stay activated when it is set to the PULSE mode The value from 0 until 999 seconds individually for each of the 6 output...

Page 31: ...set from 1 to 16 If the configuration is 2 door 2 reader unit number setting can be odd number only 01 03 05 07 09 11 13 15 If you have configured it as 2 door controller it will automatically conside...

Page 32: ...ing the matrix keypad located on the controller and not for EK9S reader keypad As any key is pressed its value will be shown on the LCD display 2 7 2 TEST READER Test Rdr This is for testing the reade...

Page 33: ...of the Door Switch DS Push Button PB Sensor 1 S1 and Sensor 2 S2 0 Contact Open and 1 Contact Closed 2 7 4 TEST OUTPUT Test OUT On entering this command the following display will show If Key 1 is pre...

Page 34: ...rly with other keys as listed below 3 General Purpose Output 3 4 General Purpose Output 4 5 General Purpose Output 5 6 General Purpose Output 6 7 Door Lock D1 8 Red LED D1 9 Green LED D1 A F1 Door Loc...

Page 35: ...program such as HyperTerminal on the PC and set it to behave as a terminal Printer Test the controller will send a stream of characters out of the serial port 2 7 6 TEST 7 SEGMENT Test 7sg As you pres...

Page 36: ...o commence testing If all the pages of the Random Access Memory RAM are good The display screen will show GOOD RAM 2 7 8 TEST ROM Test RAM This tests is the contents of the program in the Read Only Me...

Page 37: ...e device which will be retained even when power supply is switched off Press the Key to confirm 2 9 CLEAR MEMORY This command clears all memory and should be used only when you suspect corruption of d...

Page 38: ...to door 2 Door 2 readers will not accept the master card DOOR MENU PARAMETER MENU ANTI PASSBACK TIME AUTO LOCK RELEASE TIME ZONE AUTO PIN DISABLE TIME ZONE KEYPAD LOCK CARD MENU INSTALL CARD DELETE C...

Page 39: ...U VIEW TRANSACTION PRINT TRANSACTION SECOND CLEAR TRANSACTION LOG TRANSACTION SENSOR MENU DISARM SENSOR ARM SENSOR EXCLUDE SENSOR INCLUDE SENSOR SENSOR TIME ZONE OUTPUT MENU ON OUTPUT OFF OUTPUT OUTPU...

Page 40: ...TE Set Date Day Month Year Day of the Week The cursor will be blinking at the following filed You may key in the new value As for the day of the week field the value should be entered as follow Sunday...

Page 41: ...on 1 2 19 40 3 1 2 SET TIME Set Tim Hour Minute Second The cursor will be blinking at the following filed You may key in the new value 3 1 3 SET HOLIDAY Set HOL Holiday Number Month Value Day Value SE...

Page 42: ...preprogrammed using the Set Hol 3 1 4 SET TIMER Set Tmr A total of 24 timers may be programmed for each door each timer has two sets of start stop times The timers are used in other commands to set t...

Page 43: ...LOCK Adj Clk This command allows the user to calibrate the accuracy of EL2305D calendar clock It allows the user to add or subtract up to 60 seconds daily or weekly Value to be Value to be Adjusted da...

Page 44: ...our forward according to the day light saving start date and adjusted one hour backward according to the day light saving end date It allows the user to add or subtract up to 60 seconds daily or weekl...

Page 45: ...ime zone value is shown You should choose which access time zone you want Key in the starting number and ending number provided number are sequential of the card 3 2 2 DELETE CARDS Del Crd Install Car...

Page 46: ...u can select either to install cards in Door 1 or Door 2 Key in the starting number and ending number provided number are sequential 3 2 3 VIEW DATABASE View DB You can select either to view cards in...

Page 47: ...Base except that instead of showing the cards on the LCD screen the cards are sent to the communication port 3 2 5 CUSTOMER CODE Cust Code This is a 4 digit number identifying the Customer Code Cards...

Page 48: ...PROG PIN set PIN 2 you are not allowed to change the PIN value the display will show Not Allowed If PROG PIN set PIN 1 and you have not installed any card the display will show No Record Found If card...

Page 49: ...n modify its value Default setting of the PIN value is 0000 Serial No Card ID PIN Code 3 2 7 ACCESS TIME ZONE Acc TZ There are 10 time zones that can be set for each door Each time zone consists of 8...

Page 50: ...n select either to view data in Door 1 or Door 2 You can view date time card number and transaction code One transaction at a time 3 3 2 PRINT TRANSACTION Prt Trn F1 Print All Transaction Print out ev...

Page 51: ...specific holder 3 3 3 SECOND FIELD FOR TRANSACTION Se cond OFF controller will not send the second field to the software ON controller will send the second field to the software 3 3 4 CLEAR TRANSACTIO...

Page 52: ...lt setting is to record all events If you desire to record only selected activities you should change the setting to NO 3 4 DOOR MENU 3 4 1 PARAMETER MENU Par Men PERMANENT LOCK RELEASE ON OFF for kee...

Page 53: ...re mode of requiring PIN in addition to card 3 4 2 ANTI PASSBACK COMMAND OFF Anti Passback is not implemented TMR Timer Anti Passback by Timer 2RDR 2 reader Anti Passback by reader 4RDR 4 reader Not A...

Page 54: ...key in any value between 000 and 120 minutes 3 4 4 AUTOMATIC LOCK RELEASE TIME ZONE COMMAND ALR TZ The value of 01 refers to Door 1 Key in the time zone set that you already set in Time Menu 3 4 5 AU...

Page 55: ...make mistake in keying PIN number repeatedly before the card is taken out of service 3 5 SENSOR MENU ARM Sensing is Operational DISARM Sensing is Disable EXCLUDE ISOLATE To remove a sensing point fro...

Page 56: ...Sensor Command You should enter the sensor number as before Arm Sensor Command Press key to confirm Disarm Sensor Command Press key to confirm 3 5 2 AUTOMATIC OPERATION OF SENSING INPUTS It is possibl...

Page 57: ...TPUT MENU 3 6 1 ON OUTPUT COMMAND You are expected to key in any number from 1 to 6 as there are 6 output points The point selected will immediately turn on You will be able to see this only if the ou...

Page 58: ...point selected will immediately turn off as an output 3 6 3 SET OUTPUT TIME ZONE The Set Output Time Zone command allows you to program the 6 outputs to be activated automatically according to timer...

Page 59: ...rogram and monitor all access functions STAND ALONE MODE there is no PC connected However you can connect a printer or terminal to allow the controller to dump out data REMOTE MODE for testing purpose...

Page 60: ...EL1335D Access Control Panel User Guide Revision 1 2 19 59 3 9 CLEAR MEMORY This command is to clear all memory in User defined settings and return them to default values Define PIN Code 01 0000 TZ 01...

Reviews: