13
Low-speed selection key
(suction power) –
when flashing it indicates the need to wash the
fats filter.
Motor key OFF
(stand by) – excludes the
electronics – reset wash/replace filters signals.
MOTOR OFF
Press briefly to switch the motor off.
RESET FILTERS SIGNALS
After having carried out maintenance of the
filters, press the key for 3 seconds. Flashing led
1 (fats filter) or 2 (carbon filter) will stop
flashing.
EXCLUDING THE ELECTRONICS
Press the key for 3 seconds. The hood
command electronics will be excluded.
This function can be useful during the product
cleaning operations.
Just repeat the operation to reinsert the
electronics.
If the hood fails to operate correctly, briefly disconnect it from
the mains power supply for almost 5 sec. by pulling out the
plug. Then plug it in again and try once more before
contacting the Technical Assistance Service.
Using the remote control
The remote control is able to control all the functions of the
hood on condition that the “Exclusion from the Electronics”
function has not been activated (on the hood the OFF motor
(stand by) is off). In this case press the OFF motor (stand by)
key for more than 3 seconds. The key switches on and all the
electronic functions are activated:
Selecting the suction power
ON/OFF lights
Adjusting the intensity of the light (if envisaged on
the model in possession)
Resetting and configuring the filters saturation.
Selecting the suction power:
Press key "
◄
" or key "
►
" until seeing the
symbol on
the remote control.
Press key “+” or key “-” or key "
■
" respectively to increase,
diminish or turn off (stand by) the suction power.
ON/OFF light/Adjusting the intensity of light::
Press key “
◄
" or key "
►
" until seeing the
symbol on
the remote control.
Press key “+” to turn the light on.
Press key “+” to turn on and increase the intensity of the
lights.
Press key “-” to diminish the intensity of light until “soft light”.
Press key “-” to turn the light off.
Press key "
■
" to change the state of the light from OFF to ON
and vice versa.
Adjusting the intensity of light: (
i
f envisaged on the model
in possession)
Press key “
◄
" or key "
►
" until seeing the
symbol on
the remote control.
Press key “+” to turn on and increase the intensity of the
lights.
Press key “-” to diminish the intensity of light until “soft light”.
Press key "
■
" to turn the light off.
Resetting and configuring the filters saturation signal.
Switch the hood on at any speed (see above paragraph
“Selecting the suction power”).
Press key "
◄
" or key"
►
" until seeing the
symbol on
the remote control.
Resetting saturation of the filters signal.
First proceed with the maintenance of the filter as
described in the corresponding paragraph.
With the hood switched on at any speed, press keys “+” and “-
” at the same time for about 3 seconds. The relative key on
the hood sops flashing to indicate that the resetting of the
signal has been accomplished.
Activation/Deactivation of the carbon filter signal
This signal is normally deactivated. To activate it:
Press the
motor
OFF
key for more than 3 seconds. The
motor OFF
key switches off.
Press keys“+” and “-”, at the same time for about 3 seconds
Only key 1 will flash and then both will flash to indicate
activation. Repeat the operation to deactivate the signal. First
keys
1
and 2 will flash and then only key
1
to indicate
deactivation.
Maintenance of the remote control
Cleaning the remote control:
Clean the remote control with a damp cloth and a neutral
solution of detergent without abrasive substances.
Changing the battery:
•
Open the battery casing using a small screwdriver with a
flat point.
•
Change the finished battery with a new one of 12 V type
MN21/23
In inserting the new battery respect the polarity indicated
on the battery casing!
•
Close the battery casing up again.
Maintenance
Before performing any maintenance operation, isolate the
hood from the electrical supply by switching off at the
connector and removing the connector fuse.