![ELICA EWS52SS1 Instruction Manual Download Page 10](http://html1.mh-extra.com/html/elica/ews52ss1/ews52ss1_instruction-manual_2388722010.webp)
10
RUN
When unit’s compressor is running, this indicator light will illuminate to signify that cooling mode is currently in
operation.
Setting the temperature Control
Upper zone adjustable temperature: 5°C to 10°C (40°F to 50°F)
Lower zone adjustable temperature: 10°C to 18°C (50°F to 64°F)
Please note:
For optimal performance, the difference of temperatures set in the two zones should be with the
range 4~8°C
Set the desired temperature by pressing the corresponding buttons, Left
or right
to decrease. Each
press is in 1-degree increment. Once released, set temperature will flash for approximately 5 seconds then revert
back to display the internal temperature.
To view your set temperature, press either the
button once and LED display will flash set temperature for 5
seconds.
Note:
The temperature inside may vary slightly depending on whether or not the interior bulb is ON or OFF and
where the bottles are located (upper/middle or lower section).
ECO mode:
Press and hold the button
for 3 seconds to enter or exit ECO mode.
In this mode, the interior LED light, the compressor indicator
and the temperature value on the display panel
will be turned off and the symbol
°
will illuminate on the upper left corner of °C / °F.
Light
LED lamp brightness mode: with Memory IC (when unit restarts after power failure unit, will auto recover to last
setting), the default brightness is 100%.
Each time the button
is pressed, the brightness of the LED will be cycled through the four positions (100%,
75%, 50%, OFF)
Temperature Conversion
The appliance has the capability to display temperature in either Celsius or Fahrenheit. To change the temperature
scale, press and hold both