15
12. Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the
service panel before wiring this unit.
120 VAC, 15 or 20 Amp circuit
required.
ELECTRICAL
GROUNDING
INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN
ELECTRICAL JUNCTION BOX WITH 3
WIRES, ONE OF WHICH
(GREEN/YELLOW) SERVES TO
GROUND THE APPLIANCE. TO
PROTECT YOU AGAINST ELECTRIC
SHOCK, THE GREEN AND YELLOW
WIRE MUST BE CONNECTED TO THE
GROUNDING WIRE IN YOUR HOME
ELECTRICAL SYSTEM, AND IT MUST
UNDER NO CIRCUMSTANCES BE CUT
OR REMOVED.
Failure to do so can result in death or
electrical shock.
Remove the knockout and the Junction
box cover and install the conduit
connector (cULus listed) in junction box.
Run 3 wires; black, white and green
,according to the National Electrical Code
and local codes and ordinances, in 1/2"
conduit from service panel to junction
box.
Connect black wire from service panel to
black or red in junction box, white to white
and green to green-yellow.
Close and secure junction box cover.
13.
For
Ductless (recirculating)
installations
Install one charcoal filter (available as an
extra kit).
14.
Check all light bulbs to make sure they
are secure in their sockets.
Turn power (On) in service panel.
Check lights and blower operation.
15.
Install filter.
If range hood does not operate:
• Check that the circuit breaker is not
tripped or the house fuse blown.
• Disconnect power supply. Check that
wiring is correct.