LIST OF MATERIALS
Removing the packaging.
I
CAUTION
Remove carton carefully, Wear gloves to protect against sharp edges.
I
WARNING
Remove the protective film covering the product before putting into operation.
Supplied Part
Pieces
Supplied Part
Pieces
Hood assembly and
LED lamps already installed
1
Mounting brackets
2
Metal spacers (for use when cabinet
depth is greater than 12”)
2
4.5x13 mm
8
3.5x9.5 mm
6
4.2x15 mm
2
Torx #10 adapter
1
3.5x9.5 mm
4
Ø 6.4x18 mm washers
8
4.2x19 mm
8
Ø 4.2x12 mm washers
8
Parts no supplied
Tools/Materials required
đƫ
Level
đƫ
Drill
đƫ
1
⁄
8
” (3.0 mm) drill bit
đƫ
Pencil
đƫ
Pliers
đƫ
Tape measure or ruler
đƫ
Caulking gun and weatherproof caulking compound
đƫ
Flat-blade screwdriver
đƫ
Phillips screwdriver
đƫ
Saber or keyhole saw
đƫ
Metal snips
đƫ
Vent clamps
Parts needed
đƫ
6” (15.2 cm) round metal vent system
Optional accessories and consumable parts
KIT
# Part
30” (76.2 cm)
36” (91.4 cm)
Recirculating Kit
KIT02770
Hood Liner
KIT02773
KIT02774
Location requirements:
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer’s responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial
rating plate is located inside the liner behind the filter on the
left wall of the range hood.
Range hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance. Consult your
cooktop/ range manufacturer installation instructions before
making any cutouts.
Grounded electrical outlet is required.
See “Electrical Requirements” section.
The range hood is factory set for vented installations through
the roof or wall. For non-vented (recirculating) installations
see “Non- Vented (recirculating) Installation Through the
Soffit/Cabinet” in the “Prepare Location” section.
Recirculation Kit Part is available from your dealer or an authorized
parts distributor. All openings in ceiling and wall where range
hood will be installed must be sealed.
For mobile home installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
†
®