Parameter Lists
- 48 -
14.3
Parameter Axis: Analog - optional
Please note: The optional analog parameters are only displayed in the menu “axis parameter” if an analog or
PID output has been previously assigned in the menu parameter axis
X-/Y-axis
settings
axis type to the
corresponding axis (
9.4 Parameter Axis: Analog - optional).
Table 4: List of analog parameters
14.1
Parameter Axis: Measuring System - optional
This menu is used to calibrate the analog inputs, when analog measurement systems or sensors are used.
Please note: This menu contains optional parameters, which are only accessable if an analog measuring system
has been assigned to the corresponding axis in parameter axis
X-/Y-axis
settings
axis type
IN
(
9.5 Parameter Axis: Measuring System - option).
Table 5: Calibration of analog Inputs
Function
Range
Default Setting
Velocity
0 ... 9999 [U/min]
3000
Acceleration
0 ... 9999 [U/s²]
50
P-Portion
0 ... 99999
5
I-Portion
0 ... 99999
3
D- Position
0 ... 99999
1
I-Limit
0 ... 99999
10
Impulses encoder
0 ... 9999
360
Start mode
0, 1
1
Stop mode
0, 1, 2
1
Stop mode manual
0, 1, 2
1
Manual fast
0 ... 9999 [U/min]
2000
Manual slow
0 ... 9999 [U/min]
1000
v Reference mode 1
0 ... 9999 [U/min]
500
v Reference mode 2
0 ... 9999 [U/min]
250
U fast forward
0 ... 9.9 [Volt]
3.0
U slow forward
0 ... 9.9 [Volt]
2.0
U creep forward
0 ... 9.9 [Volt]
1.0
U fast backward
0 ... 9.9 [Volt]
−3.0
U slow backward
0 ... 9.9 [Volt]
−2.0
U creep backward
0 ... 9.9 [Volt]
−1.0
Function
Range
Default Setting
minimum angle, distance
−99999,9 … +99999,9 [ °, mm]
0
complies transformer increment 0 … 4095
0
maximum angle, distance −99999,9 … +99999,9 [ °, mm]
+90.0
complies transformer increment 0 … 4095
4095
Summary of Contents for P40-000 Series
Page 61: ...Accessories 61 Notes...
Page 62: ...Accessories 62 Notes...