5
Installation and Commissioning
55
Fig. 14 Installation of ELCORplus indexer device on the gas meter
Make sure the indexer counter rotates in the right direction. If not, loosen the bolts
1
,
remove the cover
2
at the back of the indexer (see Fig. 15), perform the following indexer
adjustment.
Indexer adjustment
Use Allen key size 1.5mm (it is not included) for removing the bracket, loosen the
screw in the hub of the bevel gear
3
, move the wheel out of engagement and tighten
the screw. Push the second wheel
4
into the engagement, press the teeth together
very lightly and tighten the screw.
Switch the switch
6
. The position of the switch lever must always correspond to the
position of the gear that is engaged (i.e. to the right if the right wheel is engaged or to
the left when the left wheel is engaged).
fasten back the cover
2
with screws
1
and seal the screws.
1
Indexer gasket KP067 06
2
5/16 x ¾ hexagon screw ST.5 Zn
3
Sealing screw KP 067 07
4
M8 washer DIN125-ISO7089 Zn
Summary of Contents for DATCOM
Page 38: ...3 Technical Parameters 36 ...
Page 50: ...5 Installation and Commissioning 48 Fig 7 Examples of data plates ...
Page 83: ...5 Installation and Commissioning 81 Fig 37 Communication via RS232 RS485 using B RS module ...
Page 115: ...7 Technical Description of the Device 113 Fig 57 Functional diagram of ELCOR ...
Page 116: ...7 Technical Description of the Device 114 Fig 58 Functional diagram of ELCORplus ...
Page 122: ...7 Technical Description of the Device 120 Fig 61 Modem replacement ...
Page 159: ...10 Communication with the Device 157 packet ...
Page 174: ...12 Accessories 172 Fig 78 ELCORplus example of use of external modules ...
Page 213: ...Appendix 3 Compass Data Export 211 Preview of generated document ...
Page 215: ...Appendix 3 Compass Data Export 213 3 Export to XLS 4 Export to TXT DOC ...
Page 216: ...Appendix 3 Compass Data Export 214 ...
Page 217: ...Appendix 3 Compass Data Export 215 5 Export of graph ...