3
Technical Parameters
23
Period of official metrology
check
5 years
- valid for the Czech Republic (based on Decree No.
345/2002 Coll. of the Ministry of Industry and Trade)
- vary from country to country. In general, the
validation period of a specified meter is determined
by a country's decree.
3.6.2 Pressure Measurement
ELCOR
ELCOR
plus
Number of pressure transducers,
single channel
1
1
Number of pressure transducers, dual
channel
--------------
2
Designation of the pressure
transducer
EDT 96 pressure transducer
Transducer version
internal - built-in in the device, or
external - cable length 2.5 m as a standard
(max. 100m in total for the connected EDTxx
transducers)
Sensor
silicon piezoresistive sensor
Pressure connection
6 mm tube, ERMETO M12 x 1.5 threaded joint
Measurement of gas pressure within
temperature range of
-25
+70 °C
-40
+70 °C 2
Measurement ranges - MID certified
(absolute pressure values)
80
520 kPa
200
1000 kPa
400
2000 kPa
700
3500 kPa
1400
7000 kPa
2500
13000 kPa
80
1000 kPa
8)
80
2000 kPa 8
11
400
7000 kPa 8
- Measurement error
< 0.25 % of the measured value
- Long-term stability
< 0.1 % per year of the measured value
Overload capacity without changing
metrological parameters
standardly: 1.25 x upper limit (UL)
on request: 1,5 x UL for the range 80
2000 kPa
3 x UL for the range 80
1000 kPa
8
) Extended pressure range at extra charge.
Summary of Contents for DATCOM
Page 38: ...3 Technical Parameters 36 ...
Page 50: ...5 Installation and Commissioning 48 Fig 7 Examples of data plates ...
Page 83: ...5 Installation and Commissioning 81 Fig 37 Communication via RS232 RS485 using B RS module ...
Page 115: ...7 Technical Description of the Device 113 Fig 57 Functional diagram of ELCOR ...
Page 116: ...7 Technical Description of the Device 114 Fig 58 Functional diagram of ELCORplus ...
Page 122: ...7 Technical Description of the Device 120 Fig 61 Modem replacement ...
Page 159: ...10 Communication with the Device 157 packet ...
Page 174: ...12 Accessories 172 Fig 78 ELCORplus example of use of external modules ...
Page 213: ...Appendix 3 Compass Data Export 211 Preview of generated document ...
Page 215: ...Appendix 3 Compass Data Export 213 3 Export to XLS 4 Export to TXT DOC ...
Page 216: ...Appendix 3 Compass Data Export 214 ...
Page 217: ...Appendix 3 Compass Data Export 215 5 Export of graph ...