8
THE BURNERS REQUIRE NO REGULATION OF THE PRIMARY AIR.
ABNORMAL OPERATION
ANY OF THE FOLLOWING ARE CONSIDERED TO BE ABNORMAL OPERATION
AND MAY REQUIRE SERVICING:
l
Yellow tipping of the hob burner flame.
l
Sooting up of cooking utensils.
l
Burners not igniting properly.
l
Burners failing to remain alight.
l
Burners extinguished by oven door.
l
Gas valves, which are difficult to turn.
IN CASE THE APPLIANCE FAILS TO OPERATE CORRECTLY, CONTACT
THE AUTHORISED SERVICE PROVIDER IN YOUR AREA.
l
put the knob back on and turn it quickly from the maximum position to the minimum position, checking
that the flame does not go out ;
l
for burners with safety valve make sure that the regulation obtained is sufficient to maintain heating of
the thermocouple. If it is not, increase the minimum
l
l
LPG TO TG:Use a thin blade screwdriver to turn the by-pass screw located above left of the gas
valve,shaft as shown right. Turn gently the by-pass screw clockwise to the end completely then turn it
anti-clockwise turn for the Triple ring, turn for the Fish,
turn for the Rapid,
turn for the Semi-
Rapid and
turn for the Auxiliary .
TG TO LPG: Use a thin blade screwdriver to turn the by-pass screw located above left of the gas valve
shaft as shown right.Turn gently the by-pass screw clockwise to the end.
l
l
LPG TO NG:Use a thin blade screwdriver to turn the by-pass screw located above left of the gas
valve,shaft as shown right. Turn gently the by-pass screw clockwise to the end completely then turn it
anti-clockwise 1 turn for the Triple ring,7/8 turn for the Fish,3/4 turn for the Rapid,1/2 turn for the Semi-
Rapid and 3/8 turn for the Auxiliary .
NG TO LPG: Use a thin blade screwdriver to turn the by-pass screw located above left of the gas valve
shaft as shown right.Turn gently the by-pass screw clockwise to the end.
4
1
2
1
7
8
1
3
4
1
3
8
1
1
2
l
l
NG TO TG:Use a thin blade screwdriver to turn the by-pass screw located above left of the gas
valve,shaft as shown right. Turn gently the by-pass screw clockwise to the end completely then turn it
anti-clockwise turn for the Triple ring, turn for the Fish,
turn for the Rapid,
turn for the Semi-
Rapid and
turn for the Auxiliary .
TG to NG:Use a thin blade screwdriver to turn the by-pass screw located above left of the gas valve,shaft
as shown right. Turn gently the by-pass screw clockwise to the end completely then turn it anti-
clockwise turn for the Triple ring, turn for the Fish,
turn for the Rapid,
turn for the Semi-Rapid
and
turn for the Auxiliary .