01/02/22
62000440_08_User Manual TPS/M 1500-9000VA
19
FREQ. REF
FREQ. SET
SET VOLT
DISPLAY VOLT
RANGE VOLT
SET
150
300
OUT
INT
VOLTAGE
ELETTROTEST
ELETTROTEST
SUPPLY
CURRENT
OVERVOLTAGE
UNDERVOLTAGE
LIMIT OUT
LINE
RESET
FREQUENCY
VOLTAGE
MAX OUT
V
INTERFACE
SYSTEM
OVER TEMP
INVERTER
ALARMS
SENSE
MODE
PROFESSIONAL ELECTRONICS
4
.
7
1
HARDWARE RESET
The maximum output power changes according to the nature of the connected load; in case of
resistance loads the power is nominal, in case of pure inductive loads the power increases, in
case of pure capacity load the power diminishes.
To change the range, push the button corresponding to the requested range placed on the left
of the command panel under the voice RANGE VOLT.
When the range is changed, the display showing the set voltage turns off and the output voltage
goes down slowly till zero, then the output power is switched off; after about 15 seconds the
output is switched on again and the Volts display visualizes zero voltage (0.0); since that moment
TPS/M is ready to receive on the new range.
2.5.
VOLTAGE VISUALIZATION
The display concerning the output voltage can visualize the set voltage or the output voltage with
four digits both.
At turn on, the display visualizes the set voltage and this is indicated by the led on the button SET
in the DISPLAY VOLT section of the panel.
In order to visualize the actual output voltage, push the corresponding button (OUT); the
visualized voltage indicates the output voltage with a precision of 0.3% at full scale range.
If the set voltage is changed, the display returns to show the set value.
In case of 4 wires operation, the display shows the voltage on the sense inputs.