8
1.3 POWER CALIBRATION
- FWD Power calibration
Disconnect the antenna and connect a wattmeter to the antenna connector. Give power to the amplifier until
you will read on the wattmeter a value corresponding to the equipment nominal power. Then turn the trimmer
A (see mounting plan BOTTOM - PN1071AR2, it is a variable resistor used to adjust the A analog input
measure) until you read approximately the same FWD power value on the display.
- REF Power calibration
Disconnect the antenna and connect a wattmeter to the antenna connector. Connect the Forward power
monitoring cable to the Reflected power input connector. Give power to the amplifier until you will read on the
wattmeter a value corresponding to 10% of the equipment nominal power. Then turn the trimmer B (see
mounting plan BOTTOM - PN1071AR2, it is a variable resistor used to adjust the B analog input measure)
until you read approximately the same REF power value on the display.
- UNB Calibration
Connect a wattmeter before the dummy load. Give power to the amplifier then turn off one slave module: you
will read an amount of unbalancing power on the wattmeter. Turn the trimmer C (see mounting plan BOTTOM
- PN1071AR2, it is a variable resistor used to adjust the C analog input measure) until you read approximately
the same UNB power value on the display.
1.4 RS232 AND RS485 PIN TABLES
PIN N°
SYGNAL TYPE
IN/OUT
FUNCTION
1
-
-
-
2
Digital
Input
RX2_485B-
3
Digital
Input
R
4
-
-
-
5
GND
-
-
6
-
-
-
7
Digital
Output
TX2_485Z-
8
Digital
Output
T
9
-
-
-
PIN N°
SYGNAL TYPE
IN/OUT
FUNCTION
1
-
-
-
2
Digital
Output
TX232
3
Digital
Input
RX232
4
-
-
-
5
GND
-
-
6
VDC +5V
-
-
7
-
-
-
8
-
-
-
9
-
-
-
RS232 - DB9 Connector (Front panel)
RS485 - DB9 Connector (Rear panel)
Summary of Contents for TXUP10000LD
Page 5: ......
Page 6: ......
Page 7: ......
Page 8: ...AMPLIFIER CONTROL User s manual ...
Page 21: ...14 ...
Page 22: ...15 CONTROL AND DISPLAY BOARD SCH0239AR0 SCH0239AR0 Top layer Component layout ...