8.6
How to stop the machine
8.6.1
Introduction
Please find below details on operations required to stop the machine. The operations described below are the only ones permitted
by the manufacturer
.
8.6.2
Standby
The machine will automatically suspend laser operations (the resonator shutter activates, interrupting the laser path, and the
resonator is unloaded) when the control pedal is not used for a certain time frame.
The duration of the idle period causing the laser to be put in standby can be set from the “parameters” page on the operator
panel
(paragraph 8.5.4.1).
To start using the machine again, simply press the START control on the home page of the operator panel.
8.6.3
Normal stop
To stop the machine (for operator breaks, at the end of work shifts, for calibration operations, etc.), please follow the sequence of
actions described in the following Tab. 8-5.
Symbol
Action
Feedback / notes
Remove the ignition key,
the “OFF”
state.
The machine will turn the laser source off, the
resonator shutter will close and the machine
will check that it has closed in the expected time
frame.
Remove the key from the ignition switch and give it to the person
in charge of its management.
Tab. 8-5
–
Normal stop
8.6.4
How to turn the machine off
To turn the machine off, please follow the sequence of operations described in the following Tab. 8-6.
Symbol
Action
Feedback / notes
Insert
the ignition key, the “O
N
”
state.
The machine will turn the laser source off, the
resonator shutter will close and the machine
will check that it has closed in the expected
time frame.
When the STATUS notification area on the laser operation
settings page displays the “LASER LOCKED” message, turn the
power switch to the “O” position.
Disconnect the plug from the network socket.
Always turn the machine off by first remove the key,
“OFF”
state, so that the microprocessor can unload the internal
capacitors bank; only turn off the electrical switch after the
machine is locked.