Application Examples

Automatic Playback on Power-up

1. Repeat continuously on power-up.

Intended Operation

- Play file #001 on power-up if switch #1 is turned on.
- Play file #002 on power-up if switch #2 is turned on.
.........
- Play file #008 on power-up if switch #8 is turned on.
- If more than one switch is turned on, play all corresponding

files sequentially

- Repeat the file(s) until power is turned off.

Required Text in MODE.TXT

RN

Notes

- A direct short can be used if there is only one sound file.
- If priority is required, use DN instead of RN. In this case

switch #1 has the highest priority, switch #2 has the sec-
ond highest priority, and switch #8 has the lowest priority.
If more than one switch is turned on, only the file for the
switch of the highest priority will be played.

2. Repeat at intervals on power-up.

Intended Operation

- Same as the example above but play files at intervals.

Required Text in MODE.TXT

RS
N001=F001,W06000
N002=F002,W06000
.....
N008=F008,W06000
END

Notes

- W06000 is a delay loop of 6000 x 0.1 second = 10 minutes,

so the file(s) will be played at an interval of 10 minutes, one
file at a time.

Application Examples

Using Normally Closed Switches & Sensors

Normally closed switches and sensors are often used in security
systems.

1. Play when the switch/sensor opens, with no priorities.

Intended Operation

- Play file #001 when sensor #1 opens.
- Play file #002 when sensor #2 opens.
- Repeat the sound for as long as the sensor is open.
- If multiple sensors are open at the same time, play all

corresponding files sequentially.

Required Text in MODE.TXT

RN+

Notes

- Unused inputs must be connected to the ground, as shown

in the wiring diagram.

2. Play when the switch/sensor opens, with priorities.

Intended Operation

- Same as the example above, but if multiple sensors are

open at the same time, the sensor of the highest priority
prevails.

Required Text in MODE.TXT

DN+

Notes

- The sensor connected to T1 has the highest priority, and

the sensor connected to T8 has the lowest priority.

3. Play when the switch/sensor opens, but don’t repeat.

Intended Operation

- Play file #001 when sensor #1 opens.
- Play file #002 when sensor #2 opens.
- Do not repeat the sound.

Required Text in MODE.TXT

DS+
N001=F001,J999
N002=F002,J999
H999=J999
END

Notes

- The system will stay in the “H999=J999” endless loop for as

long as the sensor is open. The system will not respond to
other sensors until this one is closed.

EM3028B / EM3028B-R / EM3028B-X  User’s Manual  -  Page 8 of 8

Summary of Contents for EM3028B

Page 1: ...on board jumper J3 to the OFF position Busy Output Terminal BY This output is manually controlled when the system runs in the Script mode In all other modes this signal is automatically turned on duri...

Page 2: ...he highest to T8 the lowest However it does not mean a higher priority input can interrupt a lower one It only means that if multiple triggers are applied at the same time the highest priority wins Ro...

Page 3: ...n all relays XFn turn off relay n EM3028B R EM3028B X only Example XF6 turns off relay 6 XFF turn off all relays EM3028B R EM3028B X only Example XFF turns off all relays Xnnn send binary to relay EM3...

Page 4: ...the selection process is finished successfully the DTE can issue one of the serial commands one byte at a time For each byte sent the DTE should expect to receive a proper confirmation within 100 ms I...

Page 5: ...f playing paused or s otherwise Query Parallel Input Status DTE Sends Q System Confirms one status byte read from the parallel input This command is usually used when the parallel inputs are con necte...

Page 6: ...ename e g 001tiger wav Note that if you want to store the maximum number of files 512 on a single flash card you should keep the filenames including the file number within 8 characters Any filename lo...

Page 7: ...s as soon as the button is released If the same button is pressed again later playing re starts from the beginning of the file instead of where it left off If both buttons are held down button 1 preva...

Page 8: ...mples Using Normally Closed Switches Sensors Normally closed switches and sensors are often used in security systems 1 Play when the switch sensor opens with no priorities Intended Operation Play file...

Reviews: