Connection diagram
Connection diagram
Pushbutton mode
The drives are actuated via the inputs I+ or I- with the
control voltage (230 V AC).
Command mode
The drives are actuated via the inputs I+ or I- with digital
command sequences. The precise connection diagram for
your relevant operating mode can be found in this chapter.
Identification number
The
elero
SMI drives are equipped with removable ID
stickers on the connecting cable. The printed SMI-Key-ID
numbers are used for unique identification of the motor in
the bus system.
Ensure the stickers and/or the connecting cable are not
mixed up. Using the stickers, you can note the installation
location for bus integration of each motor later on.
060608SMI-connection diagram_R
ev1-3.doc, 06.08.2010
Drive
Drive
Drive
Designations
Pushbutton mode
Command mode
Down
Up
I+: control cable +
I-: control cable -
PE: protective conductor (earth)
L: phase
N: neutral conductor
Steckverbindung an Leitungen Antrieb
Die Steckverbindung STAS4 von Hirschmann wird em-
pfohlen.
Leitungsanschlüsse und Steckerbelegung für
Stecksystem STAS4/STAK4 bei Leitungen mit
Adern schwarz, grau, braun, blau und gelb-grün
STAS 4
STAK 4
Aderfarbe
Bezeichnung
1
2
3
4
5 (Erde)
schwarz
grau
braun
blau
grün-gelb
I+
I-
L
N
PE
Leitungsanschlüsse und Steckerbelegung für
Stecksystem STAS4/STAK4 bei Leitungen mit 2
schwarzen Adern
STAS 4
STAK 4
Aderfarbe
Bezeichnung
1
2
3
4
5 (Erde)
schwarz 1
schwarz 2
braun
blau
grün-gelb
I+
I-
L
N
PE
Definition der schwarzen Adern:
schwarz 1: zwischen blau und grün-gelb
schwarz 2: zwischen braun und grün-gelb
Hinweise auf Verlegung von SMI-Adern in eigenen
Leitungen
Die SMI-Adern I+ und I- können in der Motoranschlusslei-
tung des SMI-Antriebes (wie oben) oder in einer eigenen
Leitung geführt werden.
Das Zusammenlegen von SMI-Adern zusammen mit
Adern fremder Signale in einer Leitung ist nicht zulässig.
Anschlussbelegung für SMI-Antriebe mit Netzspannung
Plug-in connections
Always note the applicable norms and country-specific
rules on installation.
4 | EN
©
elero
GmbH
Plug connection to drive cables
Plug connection STAS4 by Hirschmann is recommended.
Connecting cables and plug assignment for plug sys-
tem STAS4/STAK4 for cables with
black, grey, brown, blue and yellow-green wires.
STAS 4/STAK 4
1
2
3
4
5 (earth)
Wire colour
black
grey
brown
blue
green-yellow
Designation
I+
I-
L
N
PE
Connecting cables and plug assignment for plug sys-
tem STAS4/STAK4 for cables with 2 black wires.
Definition of black wires:
Black 1: between blue and green/yellow
Black 2: between brown and green/yellow
STAS 4/STAK 4
1
2
3
4
5 (earth)
Wire colour
black 1
black 2
brown
blue
green-yellow
Designation
I+
I-
L
N
PE
Notes on installation of SMI wires in own cables
SMI wires I+ and i- can be routed in the motor connection cable
of the SMI drive (as above) or in their own cable.
Combining SMI wires with wires of external signals in one cable
is not permitted.