Connection diagram 

Connection diagram 

Pushbutton mode 

The drives are actuated via the inputs I+ or I- with the 

control voltage (230 V AC). 

Command mode

 

The drives are actuated via the inputs I+ or I- with digital 

command sequences. The precise connection diagram for 

your relevant operating mode can be found in this chapter. 

Identification number 

The 

elero

 SMI drives are equipped with removable ID 

stickers on the connecting cable. The printed SMI-Key-ID 

numbers are used for unique identification of the motor in 

the bus system. 
Ensure the stickers and/or the connecting cable are not 

mixed up. Using the stickers, you can note the installation 

location for bus integration of each motor later on. 

060608SMI-connection diagram_R

ev1-3.doc, 06.08.2010 

 

 

 

 

 

 

 

 

Drive

Drive

Drive

Designations

Pushbutton mode

Command mode

Down

Up

I+: control cable +

I-: control cable -

PE: protective conductor (earth)

L: phase

N: neutral conductor

 

Steckverbindung an Leitungen Antrieb 

Die Steckverbindung STAS4 von Hirschmann wird em-

pfohlen. 

Leitungsanschlüsse und Steckerbelegung für 

Stecksystem STAS4/STAK4 bei Leitungen mit  

Adern schwarz, grau, braun, blau und gelb-grün 

STAS 4 

STAK 4 

Aderfarbe 

Bezeichnung 

5 (Erde) 

schwarz 

grau 

braun 

blau 

grün-gelb 

I+ 

I- 

PE 

Leitungsanschlüsse und Steckerbelegung für 

Stecksystem STAS4/STAK4 bei Leitungen mit 2 

schwarzen Adern 

STAS 4 

STAK 4 

Aderfarbe 

Bezeichnung 

5 (Erde) 

schwarz 1 

schwarz 2 

braun 

blau 

grün-gelb 

I+ 

I- 

PE 

Definition der schwarzen Adern: 

schwarz 1: zwischen blau und grün-gelb 

schwarz 2: zwischen braun und grün-gelb 

 

Hinweise auf Verlegung von SMI-Adern in eigenen 

Leitungen 

Die SMI-Adern I+ und I- können in der Motoranschlusslei-

tung des SMI-Antriebes (wie oben) oder in einer eigenen 

Leitung geführt werden.  

Das Zusammenlegen von SMI-Adern zusammen mit 

Adern fremder Signale in einer Leitung ist nicht zulässig. 

 

Anschlussbelegung für SMI-Antriebe mit Netzspannung 

Plug-in connections 

Always note the applicable norms and country-specific 

rules on installation. 

4 | EN  

© 

elero

 GmbH 

Plug connection to drive cables 

Plug connection STAS4 by Hirschmann is recommended. 

Connecting cables and plug assignment for plug sys-

tem STAS4/STAK4 for cables with  

black, grey, brown, blue and yellow-green wires.

 

STAS 4/STAK 4 

5 (earth) 

Wire colour 

black 

grey 

brown 

blue 

green-yellow 

Designation 

I+ 

I- 

PE 

Connecting cables and plug assignment for plug sys-

tem STAS4/STAK4 for cables with 2 black wires. 

Definition of black wires: 

Black 1: between blue and green/yellow 

Black 2: between brown and green/yellow 

STAS 4/STAK 4 

5 (earth) 

Wire colour 

black 1 

black 2 

brown 

blue 

green-yellow 

Designation 

I+ 

I- 

PE 

Notes on installation of SMI wires in own cables 

SMI wires I+ and i- can be routed in the motor connection cable  

of the SMI drive (as above) or in their own cable. 

Combining SMI wires with wires of external signals in one cable  

is not permitted. 

Summary of Contents for JA comfort SMI series

Page 1: ... pointing down Do not knock the drive shaft or coupling Do not load the drive shaft in radial direction 2 Note Secure the drive from turning in the head rail using the countersunk screws and the optional clips 3 Insert the venetian blind shafts into the QuickSnap couplings in the correct position and secure them against slipping out 127 After installation of the venetian blind attach these instruc...

Page 2: ...and continues 3 Press and hold down the OPEN button and the DOWN CLOSE button too until the desired position is reached Release both buttons The upper end position is set and is at the position before the run on end switch Cyclical reference runs are performed 4 Remove the assembly cable connect it electrically open or down close check assignment of the travel directions Setting the lower end posi...

Page 3: ...seless soft brake Rated current A 0 50 0 68 0 50 0 68 0 68 Rated power consumption W 115 156 115 156 156 Protection class I Limit switch range revolutions 100 100 100 100 100 Protection class IP 54 54 54 54 54 Operating time min S2 5 4 5 4 4 Length a mm 139 154 139 154 154 Length b mm 243 258 243 258 258 Weight kg 1 60 1 95 1 60 1 95 1 95 Ambient operating temperature C 20 60 20 60 20 60 20 60 20 ...

Page 4: ...TAS 4 STAK 4 Aderfarbe Bezeichnung 1 2 3 4 5 Erde schwarz 1 schwarz 2 braun blau grün gelb I I L N PE Definition der schwarzen Adern schwarz 1 zwischen blau und grün gelb schwarz 2 zwischen braun und grün gelb Hinweise auf Verlegung von SMI Adern in eigenen Leitungen Die SMI Adern I und I können in der Motoranschlusslei tung des SMI Antriebes wie oben oder in einer eigenen Leitung geführt werden D...

Page 5: ...n disconnected elero GmbH EN 5 060608SMI connection diagram_R ev1 3 doc 06 08 2010 Actuator Command mode Command mode in case of power failure of various phases permissible not permissible Command mode in case of power failure of various phases Command mode in case of power failure of various phases Drive Drive Drive Drive Drive Drive Drive Drive Drive permissible SMI drives to different alternati...

Page 6: ...ements and all other pertinent provisions in EU Directives For the full declaration of conformity see www elero com downloads service Manufacturer s address Service elero GmbH 73278 Schlierbach GERMANY www elero de If malfunctions have occurred or the device has been damaged despite proper handling please contact your contractor or dealer Maybachstr 30 73278 Schlierbach info elero de www elero com...

Reviews: