elero Combio-915 JA Operating Instructions Manual Download Page 8

USA/CA-13

Technical data/Troubleshooting

USA/CA-14

Troubleshooting

Problem

Cause

Solution 

No radio 

1. Transmitter is 

1. Program the

reception

not programmed.

transmitter.

2. No mains 

2. Switch on the mains

voltage.

supply again.

Bad radio 

Unsuitable receiver Change the location of

reception

position.

the receiver or the antenna.

Inverted sense Sense are program- Delete transmitter and
of rotation

med incorrectly.

program correctly.

Combio-915 JA 

Combio-915 RM

(venetian blind drives) (tubular motors)

Nominal voltage

120 V

120 V

Frequency

60 Hz

60 Hz

Max.  

450 W

450 W

Protection class

IP 54

IP 54

Permitted 
ambient
temperature

–20 to +80°C

–20 to +80°C

Radio frequency

915 MHz frequency band

Mains cable

0,5 m with 

3 m

Hirschmann plug

Motor cable

0,25 m with 

0,25 m with

Hirschmann female plug plug

Dimensions in mm L 100 x B 44 x H 15

L 100 x B 44 x H 15

Max. number
of transmitters

16

16

USA CA

Technical data

EC-Declaration of conformity

E C  -  D E C L A R A T I O N   O F   C O N F O R M I T Y

We hereby declare that the following mentioned product/s meet/s

the standards of the European Community.

Product designation:

ProLine

x

Combio-868/ -915/ -433 all versions

x

VarioTec-868 /-915 all versions

x

Revio-868 all versions

x

AeroControl-868

x

UniLogic-868/ -915

Description:

Radio receiver for controlling roller shutters,
blinds and other shading systems 

The conformity of the above mentioned products with the relevant
requirements is approved by the following directives and  standards:

x

EMC Directive 2004/108/EC

x

EN 60335-1, EN 61000-6-2, 
EN 61000-6-3, EN 61000-4-5

x

Low Voltage Directive 2006/95/EC

x

EN 61000-4-4, EN 61000-4-2

x

EN 61000-4-11, EN 61000-4-5

x

R&TTE-Directives 1999/5/EC

x

ETSI EN 301 489-3 V1.4.1

x

ETSI EN 300 220-3 V2.3.1 

x

DIN EN 60730-1 (VDE 0631 part 1); 
EN 30730-1 +A1 +A2 +A11 bis A17 

x

DIN EN 60730-2-7 (VDE 0631 part 2-7);
EN 60730-2-7 +A1 +A11 +A12 +A13 +A14

Beuren, 29.12.2009

elero GmbH

Ulrich Seeker

Antriebstechnik

– CE Officer –

Linsenhofer Str. 59–63

– Representative –

D-72660 Beuren

Summary of Contents for Combio-915 JA

Page 1: ...perating Instructions Please keep the instructions in a safe place Instrucciones de servicio Por favor conserve estas instrucciones de servicio Instru es de servi o Por favor conserve as instru es em...

Page 2: ...SA CA 12 Technical data USA CA 13 Troubleshooting USA CA 13 EC Declaration of conformity USA CA 14 Important safety indications Observe the following Instructions Danger of injury due to electric shoc...

Page 3: ...hich this risk is excluded by other safety systems The user does not have any protection from interferences from other telecommunication and terminal equipment e g including radio equipment which is o...

Page 4: ...ating mode The handheld transmitter can be used to save an intermediate position and tilting position for the slats D refer to the transmitter instructions Mounting options Combio 915 JA 1 Put the Com...

Page 5: ...horten or lengthen the antenna Pin Wire colour designation L Brown N Blue PE Green yellow Connection and installation Combio 915 JA Combio 915 JA for venetian blind drives 1 Put the drive into operati...

Page 6: ...ch Pin Wire colour designation L Brown N Blue PE Green yellow Connection and installation Combio 915 Combio 915 RM for tubular motors with plug in cable ACS E electronic drive 1 Switch off the mains v...

Page 7: ...llow Connection and installation Combio 915 RM for CSM E Combio 915 RM for elero tubular motors with fixed cable CSM E electronic drive for textile sun protection Note CSM E drives must not be connect...

Page 8: ...USA CA Technical data EC Declaration of conformity EC DECLARATION OF CONFORMITY We hereby declare that the following mentioned product s meet s the standards of the European Community Product designat...

Reviews: