elero 28890.0006 Installation Instructions Manual Download Page 8

© elero GmbH 

EN 7

Fault

Cause

Remedy

The blind 

doesn’t 

travel down in 

response to 

sunshine

The LIGHT threshold 

value is not exceeded.

Adjust the LIGHT 

threshold value

Wind alarm is active

Wait until the delay 

time has elapsed (15 

minutes).

Rain alarm is active

Wait until the delay 

time has elapsed (15 

minutes).

Roller shutter mode is not 

supported by the receiver.

Change the mode

The transmitter is set to 

MANUAL mode.

Set the transmitter to 

AUTOMATIC mode.

Poor radio connection

Change the position 

of the device.

Light sensor is dirty

Clean light sensor

The device 

cannot be 

programmed to 

recognize the 

receiver

Device is already pro-

grammed

Delete the device and 

re-program it

Poor radio connection

Change the position 

of the device.

The blind 

doesn’t 

travel down in 

response to 

darkness

The twilight threshold 

value is set incorrectly.

Adjust the twilight 

threshold value.

The twilight function is not 

supported by the receiver.

Use a different 

receiver.

The blind 

travels down 

when it is 

windy.

Device is improperly pro-

grammed

Delete the device and 

re-program it

All LEDs 

fl

 ash

Wind sensor is wet; device 

is defective

Allow the wind sensor 

to dry

Repair

Please contact your dealer if you have any queries.

Repair

Summary of Contents for 28890.0006

Page 1: ......

Page 2: ...ll safety measures are observed and met The following safety and assembly instructions apply to the device and not to the accessories and drive Failure to observe these can cause physical injury Obser...

Page 3: ...open opening retraction etc Up is used in accordance with the designation of the buttons Scope of supply Sensero 1 wall bracket 3 dowels 5 screws 1 nut Accessories Corner or mast support Item Number...

Page 4: ...close the blind manually using a hand held transmitter or an elero timer The current transitions of the light sensor measured values from 1 to 0 late in the evening or from 0 to 1 early in the morning...

Page 5: ...hed off Factory setting Level 1 Travel down at darkness Settings 2 to 13 Intermediate levels Level 14 Travel down at start of twilight Note The factory settings for OEM devices may differ from the abo...

Page 6: ...traced The measured wind value exceeds the set threshold value the wind signal is triggered Blocked for 15 to 17 min The blind moves up and remains raised for a minimum of 15 to 17 minutes Red alarm L...

Page 7: ...The set rain value is reached or exceeded Red alarm LED shines The blind travels up immediately Stop moistening the rain sen sor The set rain value is now undercut The red alarm LED flashes for 15 sec...

Page 8: ...vice Light sensor is dirty Clean light sensor The device cannot be programmed to recognize the receiver Device is already pro grammed Delete the device and re program it Poor radio connection Change t...

Page 9: ...ased sensor system Can be used in conjunction with controllers for opening and closing roller shutter and other shading systems as well as other actuators The conformity of the above mentioned product...

Reviews: