User instructions
Item of main menu� It allows to enter into the submenu System�
“System config” and “System config1”�
Items of submenu System� They allow to set the most important parameters�
“Temp U�” chooses between Celsius scale and Fahrenheit; [Show D�] set to “Always”
shows the display also in Remote Mode; [PwOscChk] set to “True” protects the amplifier
from power oscillations; [UPS T(W)] defines the Max Power Target in case of UPS; [Min
T�Sen] is the min number of thermal probes that will be taken good; [Fwd Pwr Cal� (%)]
is the adjusting for reading Fwd and Ref power; [SWR Foldback] sets the ROS protec-
tion; [IPA Bias Tres�] sets the treshold of the Bias; [Refl�Pwr T�N�(10%)] if active sets the
treshold of REF to 10% of Target Power, otherwise the value is in [Refl�Pwr T�Lev�(W)];
[PAbias (V)] sets the polarization value of RF amp modules; [Max Target Pwr (W)] is the
upper limit for the target; [Min Level Fwd Pwr Fault (W)] works in AND with the “-3dB”
alarm, depending on which one be active before�
Press “MENU” to return�