5
Pre-Installation Notes
This RO system is designed for installation under the sink, usually in the kitchen or bathroom. It can be mounted on a wall
surface or on the cabinet floor next to the storage tank. The RO faucet installs on the sink or into the counter next to the
sink. You can also install the system in any remote location from the faucet, observing the safety guides below. You will
need a nearby water supply and drain point.
Water Supply:
To provide supply water to the RO system, use the included feed supply fittings as described on page 7.
Drain Point:
A suitable drain point is needed for the reject water from the RO membrane. A floor drain, laundry tub,
standpipe, sump, etc., is preferred for remote installations. A saddle drain adapter is included to install the system under
the sink where codes permit it as an optional drain point.
NOTE:
Tubing lengths supplied with the system allow for easy moving of the filter assembly for servicing. If tubing
lengths are shortened for a neater appearance, it may be necessary to keep the filter assembly in its installed
location for service. Please keep connecting tubes as long as possible for convenient usage.
CAUTION:
A refrigerator icemaker may not operate properly when connected to an RO system that has been
installed on a water system operating outside of the specified pressures listed on the
Performance Data Sheet.
CHECK YOUR WATER SUPPLY:
The COLD water supply to the RO system must be within certain quality limits. See
the
Performance Data Sheet
. If the supply water is not within the limits defined, the RO system will not filter
water as it should and will substantially reduce the filter and membrane life.
CAUTION:
Chlorine in water will destroy the RO membrane. Most municipalities add chlorine to the water supply
to kill water-borne infectious organisms. The pre-filters will remove the chlorine up to the limits shown in the
Performance Data Sheet
before it enters the RO membrane. It is important to replace the pre-filter cartridges at
the recommended time intervals. See the filter change-out procedures and the
Performance Data Sheet
.
CAUTION:
Before consuming any water from the RO system you must purge the RO membrane cartridge. The RO
cartridge contains a food grade preservative that should be removed before consuming the water from the
system. This procedure is explained on page 11.
DO NOT
attempt to use this product to make safe drinking water from non-potable water sources. Do not use the
system on microbiologically unsafe water, or water of unknown quality without adequate disinfection before or after the
system. This system is suitable for cyst reduction and may be used on disinfected water that may contain filterable cysts
per the
Performance Data Sheet
.
Check with your local public works department for applicable plumbing and sanitation codes. You must follow their
guides as you install the system. Follow your local codes if they differ with guidance in this manual.
This reverse osmosis system works on water pressure of 40 psi minimum to 87 psi maximum. You must install a
pressure reducing valve in the water supply pipe to the reverse osmosis system if the water pressure exceeds 87 psi.
DO NOT
install this reverse osmosis system outdoors or in extreme hot or cold environments. Temperature of the feed
water supply to the RO system must be between 39⁰ F to 100⁰ F.
Do not install on hot water.