8
INSTALLATION AND USER MANUAL
EN1856-1 T600 N1 D Vm L50040 G0
EN1856-1
= Norm number
T600
= Temperature class
N1
= Pressure density
N = Under pressure
P = Over pressure
H = High over pressure
D
= Condensation resistance
D = Dry
W = Wet
Vm L50040
= Corrossion class + material types
Thickness of the inner flue
G0
= Chimney fire resistancy
(G = Yes, 0 = No)
Distance to flammable material (in mm)
1.4 Flue material
The PowerFan can be connected with the following brands of
flue gas pipes.
Concentric
•
OnTop / Metaloterm (eg the SU line)
•
Jeremias
•
Poujoulat
•
Other flue material that has been tested according to the
applicable standards.
Single walled
•
Flexible tube
•
Rigid tube, such as
•
Ontop Metaloterm (eg the ME line)
•
Jeremias
•
Poujoulat
Ensure that the used flue materials meet the requirements for
the conditions of use specified in this manual. The performance
declaration provides more information on this (see
Table 1.1
).
Table 1.1
V+
V0
RUN
FAN
RELAIS
AU
X
MODULE
Fan
Module
Gaspipe to
Burner
To
PowerFan
MkIII
Gas Block
Receiver
Figure 1.3 - Connection scheme PowerFan MkII
Figure 1.2 - Mounting possibilities PF MkII