background image

6

Chapter 5 

I N S T A L L A T I O N   M A N U A L   |

CONNECTION

5�1 

ELECTRICAL

This appliance must only be connected to a 230/240 Volts AC 50Hz 

supply. Before connecting the fire, check that the supply voltage is the 
same as stated on the fire.

It is important that the outlet is located outside the installation location 
so that the socket is easily accessible and the plug  can be disconnected 
from the stove after installation.

After the fire is attached to the wall and connected to the socket, the 

surround (the chimney) can be placed around it.

This appliance must only be used on a AC supply, fuse rating 13Amp. The 
wires in the mains lead are coloured in accordance with a standard UK 
supply, these being:

• 

GREEN/YELLOW – EARTH

• 

BLUE – NEUTRAL

• 

BROWN – LIVE

As the colours of the mains lead of this appliance may not match the 
coloured markings used to identify the terminals in a plug, please 
observe the following

• 

The green and yellow wire must be connected to the terminal in the 
plug which is marked with the letter E or Earth symbol.

• 

The blue wire must be connected to the terminal in the plug which 
is marked with the letter N.

• 

The brown wire must be connected to the terminal in the plug 
marked with the letter L.

• 

Replace fuses only with fuses of the correct size and rating.

Figure 5.1  | 

Posi tion of main power supply at the back 

Figure 5.2  | 

Posi tion of the On/Off swi tch

5�2 

MAINTENANCE

Maintenance to this device may only be done by a qualified professional. 
It  is  adviced  to  maintain  your  fire  at  least  once  every  12  months. 

 

WARNING: 

Before repaires or maintenance check whether the fire is unplugged. 

CAUTION

In order to avoid a hazard due to inadvertent resetting of the thermal 
cut-out,  this  appliance  must  not  be  supplied  through  an  external 
switching  device,  such  as  a  timer,  or  connected  to  a  circuit  that  is 
regularly switched on and off by the utility.

Your main power supply is attached to the IEC through the back of the 

fire, see 

Figure 5.1

The on/off switch to activate connection to your app or E-Tab is located 
at the front of the fire, in the gap   between the front glass panel and the 
bottom edge of the frame, offset to the right hand side. 

Figure 5.2

Summary of Contents for KUDOS-E

Page 1: ...INSTALLATI O N MA NUAL INSTALLATI O N MA NUAL Please leave these instructions behind with the device K U D O S E...

Page 2: ...CHILD SAFETY 5 4 2 GENERAL WARNINGS 5 5 CONNECTION 6 5 1 ELECTRICAL 6 5 2 MAINTENANCE 6 6 INSTALLATION REQUIREMENTS 7 6 1 HEATER UNIT CUT OUT 7 6 2 SERVICING 7 7 INSTALLATION METHOD 7 7 1 PRODUCT SIZE...

Page 3: ...device show defects within 24 months of purchase due to shortcomings in construction material or workmanship the product will be repaired free of charge under the following conditions It is the respo...

Page 4: ...o not cover cord with throw rugs runners or the like Arrange cord away from traffic area and where it will not be tripped over 12 Do not locate the heater immediately below a fixed socket outlet 13 Do...

Page 5: ...derstand the hazards involved Children aged from 3 years and less than 8 years shall not plug in regulate and clean the appliance or perform user maintenance CAUTION Some parts of this product can bec...

Page 6: ...marked with the letter E or Earth symbol The blue wire must be connected to the terminal in the plug which is marked with the letter N The brown wire must be connected to the terminal in the plug mar...

Page 7: ...irflow to the product It is also important to ensure that the product has a minimum clearance around it of 15mm this is to ensure that the product can circulate the required airflow to the heater unit...

Page 8: ...are 2 in each bracket one on the left and one on the right See Figure 8 2 Once you have found the key hole slots lift the front glass panel vertically then towards you to release the brackets See Fig...

Page 9: ...and complete the layout by adding the D logs on either side See Figure 9 4 9 DECORATION INSTRUCTIONS The Kudos e comes with a ceramic decoration set This set does not influence the workings of the fi...

Page 10: ...The App Control can be used on either OS or Android operating systems To obtain the App please visit either the OS App Store Or Google Play and follow the on screen instructions Figure 10 1 Home Scree...

Page 11: ...t If problem persists replacement fan may be required 3 Noisy Heater Fan unbalanced Adjust fan to stop catching on the case If problem persists replacement fan unit maybe required Fan catching on hous...

Page 12: ...n PCB PCB needs replacing 7 Heater coming on randomly Timer has been accidentally set Double check timer settings Thermostat faulty Replace PCB 8 LED streaking LED dropped down LED needs to be re stuc...

Page 13: ...Paxtonstraat 23 8013 RP Zwolle The Netherlands Info element4 nl www element4fires com 25 03 21 ELEMENT 4 B V RELEASE DATE...