CLEARANCES
B
B
A
TYPICAL CLEARANCE DIAGRAMS
Minimum Distances
A
Room ceiling to
appliance bottom
72”
1830
mm
B
Room ceiling to top of
Convection Air Outlet
1”
25
mm
Air Outlet Area by Model
Model
Square
Inches
Square
Centimeters
Any
126
813
The total area of the air openings must be maintained. The location of the openings must allow for the free movement of air and
must not allow excessive warm air to build up within the chase.
The top of the Warm Air Outlet must be
no more
than 1” (25 mm) down from the
chase
ceiling.
The minimum distance from the bottom of the appliance to the room ceiling is 72” (1830
mm)
.
Air Outlet
18
Figure 21
Figure 22
Figure 23