Element ELCG-02ASP Instruction Manual Download Page 3

 

3

<Features>         
This product is a control unit, corona discharge electrode work stand unit a desktop a 
corona electrode elctrification system that integrates the. Weight about 23kg 
The  Y-axis  electric  cylinder  moves  200  mm  in  the  Y  direction  to  perform  corona 
charging.to hold. The work table size is 180 x 180 mm. 
16 pieces of work Φ37mm and t = 1mm or less can be mounted.∙ Corona electrode and 
grid electrode on two pairs of manual Z-axis stages .The height can be adjusted. 
 

<Specification> 
Control unit 
1, high voltage power supply 
 

(1) Corona discharge power supply: 0 to +15.00 kV 1.999 mA Maximum         

applied voltage 0 to + 9kV 1.999mAOutput voltage control CV 1 piece 

Switchable output voltage and current display digital panel meter 

 

(2) Power supply for grid electrode 0to + 3kV 2mAOutput voltage control 
CV 1 piece Switchable output voltage and current display digital meter 
 
(3) HV ON switch 1 mini toggle switch High voltage ON when ON1 
 

(4) kV / mA switch Mini toggle switch For switching digital panel meter 

   

(5) High voltage output section15kV connector 1 piece1 MHV connector 

   

 

2, work table control switch 
 
(1)

 

EMG emergency stop switch 
 

(2)

 

Buzzer reset switch 

 

(3) AUTO switch when ON, AUTO when OFF, manual MAN   
 
(4) 1, 2, 3 switch AUTO OFF   
1,    electrification process 26 SEC .

 

return to origin 6.5 SEC   

2,    electrification process 13 SEC.    return to origin 6.5 SEC   
3 ,    electrification process 6.5 SEC.    return to origin    6.5 SEC 
   
(5) STANDBY switch Used when returning to origin When   
* POWER is ON, be sure to press once before operating each switch. 