LIMIT SWITCH - ADJUSTMENT
Working limit adjustment is complete
The door could be moved in DEADMAN mode UP/DOWN
Further adjustments see programming mode (Page 16)
1. Move the door to final open position
press button to reach upper limit
Door open
2. Adjustment final open limit
3. Move the door to final close position
press button to reach lower limit
Door close
4. Adjustment final close position
After checking the phase rotation, the limit switches must be adjusted in the following steps.
When open and close position limits have been set the safety limits are automatically
pre-adjusted. Eventually fine adjustment could be required. Please see Mechanical
Operating Instruction.
After reaching the final open
position the limit S3 must be
switched with green limit cam S3
and panel display changes to
„Door final open position“
After reaching the final close
position the limit S4 must be
switched with green limit cam S4
panel display changes to „Door
final close position“
Display shown-
door open
Display shown-
door closed
Display flashing
during the door
upwards movement
Display
shown - door
between final
limit positions
Display flashing
during door
downwards
movement
Display shown-
door between
final limit
positions