ELEKTROBOCK PT23 Quick Start Manual Download Page 5

5

RELAY TEST

SOUNd OF bU

yYES

PROG

Setting the weekly program with up to 6 changes per day.

CONST

Setting the control parameters.

1

2

3

ENGLISH

The hysteresis can be set from 0,1 to 6°C. Example: If the hyste-

resis is 1 °C and the required temperature 20 °C, the thermostat 

switches off at 20 °C and on again at 19 °C. By using “ 

 “ 

buttons set required value and press the “ 

 “ button to confirm.

4

TOUCH SOUND

Press twice the“  

  

button

, by using “ 

 “ buttons choose the PROG mode 

and press the“ 

 “button to confirm. The number of days to be programmed is 

flashing on the display, by using “ 

 “ buttons choose on of the option (you 

can program day-by-day or 1-5 = Mon-Fri, 6-7 = Sat-Sun or 1-7 =Mon-Sun) and 
press the“   “ 

button to confirm

The 1st change time

 starts flashing, by using “ 

 “ buttons set time and 

press the“ 

 “ button to confirm. To this time assign with “ 

 “ buttons the 

temperature and press again the“ 

 “ button to confirm. 

The 2nd change time

 

appears on the display. Proceed in the same way as with the first change setting. 

In 

this way, you can set up to

  6  temperature  changes  per  day.

 To return to 

the menu, press the “   “ button. After changing the preset program, check 

whether all the changes made conform to your requirements!

It is not necessary to apply all six changes in one day!

Press twice the “ 

 

“ button, by using “ 

 “ buttons choose 

CONST mode and press the“   “ button to confirm.

Language selection (CZ/PL/EN/DE/RU/SK).

By using “ 

 “ buttons choose languge and press the“   “ 

button to confirm.

HYSTERESIS

TEST

We recommend you to use the test when you first use the 

thermostat!

By using “ 

 “ the test starts and the output relay is switched 

on/off several times (the display shows the ON/OFF message) 

Pressing the “   “ button, you can view the next constant; to 

return to the main menu press the “   “ button.

By using“ 

 „ buttons you can switch on and off the sound of 

buttons. 

(PROGRAMMING)

(CONSTANTS)

(English language set by default)

(0.5°C set by default)

PROGRAMMING

SELECT  dAY

TIME  CHANGES

CONSTANTS

ENGLISH

HYSTERESIS

Summary of Contents for PT23

Page 1: ...s with ON OFF weekly program preset 6 temp changes per every day anti freeze mode easy installation modern design for all types boilers with LARGE WELL ARRANGED DISPLAY WITH TOUCHING CONTROL ROOM THERMOSTAT WITH BACKLIT DISPLAY ...

Page 2: ... 3 Chip away the central plastic piece from the lower cover to lead in conductors 4 Run the conductor through the hole and connect it to the terminal acc to the diagram 5 Fasten the lower cover to the wiring box with screws Fig 2 6 Batteries are located at the back of the control part Remove their protective paper on first use or insert new batteries Fig 3 7 Mount the control part on the lower cov...

Page 3: ... on the display you must replace the batteries 1 Remove the control part from the lower cover of the device Fig 1 2 Replace the batteries Heed the correct polarity marked in the battery compartment Fig 3 After removing the batteries all setting of the thermostat are saved in the memory 20 sec only Always use the type AA 2x1 5 V alkaline batteries Recommendation Check the batteries before every hea...

Page 4: ... confirm with the button weekly program is factory set see page 8 Press the button twice using the buttons choose the MANU Mode and confirm with the button anti freeze temperature of 3 C is kept can not be changed Press the button twice using the buttons choose the OFF Mode and confirm with the button Press the button twice with buttons choose the and confirm with the button Stepwise set the tempe...

Page 5: ...the button to confirm The 2nd change time appearsonthedisplay Proceedinthesamewayaswiththefirstchangesetting In this way you can set up to 6 temperature changes per day To return to the menu press the button After changing the preset program check whether all the changes made conform to your requirements It is not necessary to apply all six changes in one day Press twice the button by using button...

Page 6: ...Status line dynamically changing according to the process running 14 Low battery indication TIME CHANGE YES VERSION DISPLAY DESCRIPTION 5 6 SUMMER WINTER time change VERSION restoring the default settings By choosing YES with buttons you can activate automatic SUMMER WINTER time change according calendar You don t need to take care about the time change thermostat make automatic setting for actual...

Page 7: ...e Setting of week programms P1 P2 AUTOMATIC MODE MANUAL MODE OFF MODE thermostat is permanent switched OFF Antifreeze protection 3 C is still active HOLIDAY Setting of required temperature and point of holiday ending Summer winter time change Firmware version factory setting Touch sound 2 or Clock Setting Programming Constants level 0 level 1 level 2 CONTROL MENU PROGRAMING METHOD HOLIDAY ...

Page 8: ...ies preset weekly program powered by batteries 2 x 1 5 V AA 6 temp changes per day programming by 10 minutes and 0 5 C programming day by day or Mon Fri Sat Sun or Mon Sun anti freeze protection 3 C short term change in the required temp auto SUMMER WINTER time change big backlit display output potential free contact max 5 A 250 V AC intuitive navigation in the selected language CZ SK PL EN DE RU ...