1.9.3 Scope of delivery
1 x Electronic load cabinet with 2-6 installed PSI 9000 3U units
1 x 1.8 m USB cable
1 x USB stick with documentation and software (for the cabinet, further USB sticks from the power module may
be included)
1.9.4 Accessories
For these devices the following accessories are available:
IF-AB
Digital interface modules
Pluggable and retrofittable, digital interface modules for RS232, CANopen,
Ethernet, Profibus, ProfiNet, ModBus TCP, EtherCAT or CAN are available.
Details about the interface modules and the programming of the device using
those interfaces can be found in separate documentation. It is usually available
on the USB stick, which is included with the device, or as PDF download on the
manufacturers website.
EL 9000 B SLAVE
Additional slave units
Some models in this series have a spare slot for one additional slave unit which
can be retrofitted by the operator of the cabinet (see
).
The slave unit can be ordered by its article number and retrofitted on location. A
patch cable for master-slave bus connection of the additional slave is included.
Retrofitting may also require to install further DC bus bars to match the DC bus to
the final current the system will have. Contact us for details and a proper quote.
Following slave units are available:
Model
Article number Can be installed in
EL 9080-510 B 3U Slave 33290270
EL 9080-1530 B 15U
EL 9080-2550 B 24U
EL 9200-210 B 3U Slave 33290271
EL 9200-630 B 15U
EL 9200-1050 B 24U
EL 9360-120 B 3U Slave 33290272
EL 9360-360 B 15U
EL 9360-600 B 24U
EL 9500-90 B 3U Slave 33290273
EL 9500-270 B 15U
EL 9500-450 B 24U
EL 9750-60 B 3U Slave 33290274
EL 9750-180 B 15U
EL 9750-300 B 24U
1.9.5 Options
These options are usually ordered along with the device, as they are permanently built in or preconfigured during
the manufacturing process.
EMERGENCY OFF
Emergency off system
Optional emergency off system consisting of a manual emergency off switch
(mounted on top of the cabinet), a contactor and a connector for additional external
contacts (breaker) to extend the circuit. In an emergency off situation the contactor
will cut all units in the cabinet from AC supply so they stop supplying DC power.