 -                                     MY575 WASH 

 

- Main menu 5 

 
1.

 

Press 

[ENTER]

 for 3 seconds to enter the main menu 

(display flashing). 

2.

 

Press 

[UP]

 to select 

“EDIT”

 

- Define the number of steps in Run 

With this function you can define the number of steps in the 
Program Run. 
1.

 

Select 

“STEP”

 by pressing 

[UP]

 button. 

2.

 

Press

 [ENTER]

, the display shows 

“S-XX”

, “X” stands   

for the total amount of steps you want to save, so you can   
call up to 48 scenes in 

“RUN”

. For example if the “XX”   

is 05, it means that 

“RUN”

 will run the first 5 scenes you   

saved in 

“EDIT”

3.

 

Press 

[ENTER]

 to save and exit. 

 

- Editing the channels of the individual scenes 

With this function you can edit the program to be called up in 
Run. 
 

a) Editing via the Control Board 

1.

 

Select 

“SC01”

 by pressing 

[UP]

 button. 

2.

 

Press 

[ENTER]

, the display shows 

“SCXX”

, “X” stands   

for the scene no. to be edited. 

3.

 

Change the scene no. by pressing 

[UP]

4.

 

Press 

[ENTER]

, the display shows

 “C-X”

, “X” stands   

for the channel no. Such as 

“C-01”

, it means you are   

editing channel 1 of the selected scene. 

5.

 

Select the channel no. you would like to edit by pressing 

[UP]

6.

 

Press 

[ENTER]

 to enter editing for the selected channel , 

MY575w

 reacts to your settings. The display shows 

the DMX value of the edited channel. Such as “ 11XX”, it stands for in the channel 11 of the editing scene, the 
DMX value is XX , XX is a hexadecimal number value “01-FF”. 
7.

 

Adjust the desired DMX value by pressing 

[UP]

 or 

[DN]

8.

 

Press 

[ENTER]

 in order to edit other channels of this scene. 

9.

 

Repeat steps 5-9 until you finish setting all the DMX values for all channels of this scene. 

10.

 

Once all the channels completed, the display will flash   

“tIME”

 

11.

 

Press 

[ENTER] 

to edit the time needed, the display shows “t--X”,“X” stands for the time needed to run the 

current scene, value “1-9”. For example, “t--2” means you need 2 seconds to run the current scene. 
12.

 

Adjust the desired time by pressing 

[UP]

13.

 

Press 

[ENTER]

 to save the settings for the scene you are editing, the display will change to the next scene 

automatically. 
14.

 

Repeat step 3-14 to edit and other scenes, you can edit and save a maximum of 48 scenes. 

15.

 

Press 

[EXIT/DN]

 to exit. The number of steps can be defined under 

“STEP”

 and the scenes can be called up 

under 

“RUN”

 

Summary of Contents for MY575w

Page 1: ...MY 575w USER MANUAL V2 05 From Serial number ele632sp008...

Page 2: ...ired 9 Speed of pan tilt movement adjustable 9 Advance Color mixing system Cyan Magenta Yellow The colors range goes extremely deep giving the Lighting Designer a large palette of colors 9 Additional...

Page 3: ...hot to touch Please keep MY575w away from children and the general public Please be intelligent and use common sense when operating MY575w General Guidelines MY575w is a lighting fixture for professi...

Page 4: ...A B C on the bottom of the housing holding the plate under which the lamp is located Carefully remove the metal plate 2 Carefully insert the lamp into the socket Please remember the lamp is polarized...

Page 5: ...ing used Periodic safety inspections should be done of MY575w as the fixture does move If you do not have the qualifications and experience do not attempt the installation Improper installation can re...

Page 6: ...ing the correct number on the display located on the base of MY575w You can set the same starting address for all fixtures or group of fixtures like all the MY575w s in your plot or you can make diffe...

Page 7: ...wn buttons to change the address 2 The default for the lamp striking is from the board channel 14 The fixture s lamp will not just start up when you turn on the fixture The main menu is accessed by pr...

Page 8: ...ONLI ON OFF Lamp on off via controller 1 LAMP DELA D 00 D 59 D 15 Delay lamp on RPAN ON OFF Pan Reverse VER V1 0 V9 9 Software Version LODA ON OFF Restore Default factory setting REST ON OFF Reset DE...

Page 9: ...T DN to return to main menu Slave setting With this function you can define the device as slave 1 Select SLAV by pressing the UP button 2 Press ENTER the display shows ON or OFF 3 Press UP to select O...

Page 10: ...el If you select D 14 the display will only show the DMX value of the 14th channel 4 Press ENTER to confirm 5 The display shows D XX X stands for the DMX value of the selected channel 6 Press ENTER or...

Page 11: ...th this function you can switch the lamp on or off via an external controller 1 Select ONLI by pressing UP button 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON if you wish to enabl...

Page 12: ...0 3 Press UP to change the selection 4 Press ENTER to save and then EXIT DN to exit Switch 16 bit 8 bit With this function you can switch MY575 from 16 bit to 8 bit resolution 1 Select 16BI by pressin...

Page 13: ...n adjust the lamp via the Display Panel The shutter opens and the lamp can be adjusted In this mode MY575 will not react to any control signal 1 Select LADJ by pressing UP button 2 Press ENTER the dis...

Page 14: ...mber of hours 3 Press ENTER or EXIT DN to exit Clear fixture time With this function you can clear the running time of MY575 1 Select CLMT by pressing UP button 2 Press ENTER the display shows ON or O...

Page 15: ...ect the channel no you would like to edit by pressing UP 6 Press ENTER to enter editing for the selected channel MY575w reacts to your settings The display shows the DMX value of the edited channel Su...

Page 16: ...pressing UP 5 Press ENTER the display shows OFF 6 Press UP the display shows ON 7 Press ENTER the display shows SC02 You successfully downloaded the first scene 8 Adjust the Step time as described ab...

Page 17: ...osition 32 63 DMX value CHANNEL 12 Speed channel for C Y M from maximum speed to minimum CHANNEL 13 Macros for C Y M color effects engine CHANNEL 14 Control channel for lamp ON lamp Off motor reset Al...

Page 18: ...al 71 230 Beam shaper 231 255 Frost filter Channel 9 Zoom 0 255 Zoom 28 Zoom 7 Channel 10 Shutter strobe 0 31 Shutter closed 32 63 No function shutter open 64 95 Strobe effect slow to fast 96 127 No f...

Page 19: ...12 224 231 Macro28 104 111 Macro13 232 239 Macro29 112 119 Macro14 240 247 Macro30 120 127 Macro15 248 255 Random CMY Channel 14 Lamp on off reset internal programs 0 19 color change normal by directi...

Page 20: ...ot located in the default position after the reset 06Er Tilt head movement error This message will appear after the reset of the fixture if the head s magnetic indexing circuit malfunctions sensor fai...

Page 21: ...causes premature failure of the lamp and other critical components There are no serviceable parts inside MY575w except for the lamp Please refer to the instructions under Installation instructions Sho...

Page 22: ...MY575 WASH Other Elektralite Products include Also check out our website at www myelektralite com CP 3 Controller CP 10xt Controller CP 16 24 Controller...

Page 23: ...MY575 WASH CP 20xt Controller TurboFog Fog Machine...

Page 24: ...MY575 WASH Turbohazer Haze Machine...

Reviews: