3. General Guidelines. 

The 

Elektralite lightStream 

is a lighting fixture for professional use on stages, in churches, theatres, etc. 

The 

Elektralite lightStream 

should only be operated at between 120 to 240 volts and only indoors. By 240 volts we mean that the 

neutral must remain a neutral and NOT be used as one phase in a 120v circuit to create 208 volts across the 

Elektralite 

lightStream. 

The reason for this is simple, the neutral is not protected with a fuse. Any problem with that phase will not be protected 

by the 

Elektralite lightStream.

 

The 

Elektralite lightStream 

should not be operated 24/7 (24 hours a day; 7 days a week). The 

Elektralite lightStream 

needs 

operation breaks to ensure that it will work for a long time without problems. Please do not shake 

Elektralite lightStream 

and avoid 

using brute force when installing or operating it. 
When choosing the location to install the 

Elektralite lightStream

, please make sure that it is not exposed to extreme heat, moisture 

or dust. The minimum distance between the 

Elektralite lightStream 

and the illuminated surface must be more than 3 feet. 

Always mount the 

Elektralite lightStream 

with an appropriate safety cable/chain. 

Operate the 

Elektralite lightStream 

only when you are familiar with the features of the fixture. Do not permit operation by persons 

not qualified to operate it. 
All modifications to the 

Elektralite lightStream will invalidate the warranty. There are absolutely no exceptions. That includes 

operation of the fixture at 208v using two different 120v phases.

 

If 

Elektralite lightStream 

is operated in any way different to the one described in this manual, the 

Elektralite lightStream 

maybe 

damaged and the guarantee will be void. 
 

4. Installation   

Please ensure that the 

Elektralite lightStream 

is hung using the appropriate "C" clamps or half cheeseboros and the U brackets 

that come with the 

Elektralite lightStream

. A safety chain or cable should also be used as a secondary point of holding the fixture 

in case the clamp comes loose. 

Never hang the fixture without a safety chain or cable

Mount the  

Elektralite lightStream 

either vertically upright or vertically down. DO not mount the  

Elektralite lightStream 

sideways. 

If you are not qualified or have any doubts about hanging the 

Elektralite lightStream, 

then do 

NOT

 hang it. 

Do not clamp the cable to the U bracket or clamp. That is not a secondary safety point. 
A secondary safety point is any point that will adequately hold the 

Elektralite lightStream, 

if the "U" brackets, "C" clamps or half 

cheese-boros fail. Then the safety cable would be the backup and stop the 

Elektralite lightStream

 from falling to the ground. So do 

NOT

 fix the safety to the same place that the "C"clamps/half cheese-boros are attached. 

                                                      

 
 
 

 

 

Summary of Contents for lightStream

Page 1: ...ElektraLite lightStream USER MANUAL Version 1 02 Elektralite a division of Group One 70 Sea Lane Farmingdale NY11735 U S A T 1 631 396 0184 F 1 631 396 0190 WWW MYELEKTRALITE COM...

Page 2: ...es written in this user manual The Elektralite lightStream is a high voltage fixture Be careful when dealing with high voltages Please read this manual If you do not read this manual and damages occur...

Page 3: ...e fixture Do not permit operation by persons not qualified to operate it All modifications to the Elektralite lightStream will invalidate the warranty There are absolutely no exceptions That includes...

Page 4: ...below Please remember the DMX signal has a maximum transmission distance of just 300 feet from controller to the last fixture So don t use 50 foot cables when you only need 10 or 15 foot cable runs 1...

Page 5: ...Shutter Functions 0 15 Pulse effect Forward See ch7 16 31 Pulse effect Reverse See ch7 32 47 Random Strobe See ch7 48 63 Effect See ch7 64 95 Not used 80 255 7 10 Shutter Normal Shutter Functions Clos...

Page 6: ...ounce See ch10 ch11 080 111 Not used 128 255 10 13 9 12 Virtual Color 1 CTC Function ch9 must be set at between 16 31 CTC Color Temperature Correction 2000K 2700K 000 223 White 3200K 224 231 White 420...

Page 7: ...252 255 12 15 11 14 LED 1 Also known as Color A Black out 000 003 Going through the colors from red green blue white 004 243 Red 244 245 Green 246 247 Blue 248 249 White 250 251 Blended white using al...

Page 8: ...t See below 016 023 Not used 024 031 Not used 032 039 Not used 040 047 Not used 048 055 Display Off 056 063 Display On 064 071 Not used 072 079 Not used 080 087 Hibernation see menu section 7 for expl...

Page 9: ...se effect Forward for the shutter is achieved by setting channel 6 between 016dmx 031dmx and then ch7 becomes the speed control for the Pulse effect Forward 000dmx value being the slowest speed and 25...

Page 10: ...s Pan Tilt Mode ON OFF ON OFF 630 540 ON OFF Standard Smooth Pan Reverse Tilt Reverse Choose Pan Degree Encoder wheel on off Choose pan tilt mode UI Set Mic Sens No Signal Temperature C F Fans Mode Hi...

Page 11: ...2 or 3 respectively Edit Chase Chase 1 thru Chase 8 are available Chase Test Step 01 Step 64 Scene 1 thru 250 Scene 1 thru 250 Tests out the chase It displays the step and scene being used This makes...

Page 12: ...l and that will be a lot more costly than having someone vacuum the fixtures on a regular basis How often should the fans be cleaned It depends on where the fixtures are in a very dusty atmosphere onc...

Page 13: ...s Using 18 high powered 12 watt leds Check out the website for light output figures the ElektraLite 1018 is available using 4 in 1 This is the first true LED audience blinder or 6 in 1 leds Each led c...

Reviews: