![elektraLite eyeBall User Manual Download Page 6](http://html1.mh-extra.com/html/elektralite/eyeball/eyeball_user-manual_2386566006.webp)
7. Static Look.
The
ElektraLite WW
can be set to a single static look quickly.
Use the Menu button to get to STAT.
Press Enter.
The next screen will read Warm 000. This is addressing the WW leds.
Use the ↑ or ↓ to increase brightness of the cool leds.
Numbers are expressed in DMX values so 0 is no output and 255 is highest output.
Press Enter to save the value.
The screen will automatically advance to the strobe function.
If the strobe function is to be in the static look, then use the ↑ or↓ to crease the value of strobes flash rate.
Press Enter to save the value.
This is the last entry and the static look is complete. Pressing the Enter key just continues around if you
need to make fine adjustments to the static look.
Do not press MENU as this will get you out to the Root directory and out of the static look.
8. Auto Programs.
In Auto Program there are three programs (or shows) in the
ElektraLite WW
are Effect 1, Effect 2 and
Effect 3. Chose the one best suit for the venue.
To run a color or program in Auto mode use the Menu button to get to AUTO.
Press ENTER.
Use the ↑ or ↓ key to get to the program. Press Enter.
The program will start running.
9. Run.
Run allows the fixture to operate in either DMX or Slave operation.
Using the Menu button in the root menu go to RUN.
Press Enter to get to DMX mode. To get to SLAV mode use the ↑ or ↓
And press enter to save this setting.
10. Address (For DMX & ID)
DMX Address
Sets up the address for the dmx.
Using the Menu button in the root menu go to DMX
Press Enter to get into DMX and the display will read the current dmx channel.
The display will read for example
DMX:
001
This means the fixture's current address is
1
To change it, use the ↑ or ↓ buttons to get to the correct address. Press Enter to save the address.
Now immediately Enter is pressed, the ID address for the fixture is shown. See below for ID address
information; otherwise press Enter to exit out and back to the Root Menu again.
ID Address
An
ElektraLite WW
can be addressed (controlled) through the dmx or instead it can have its own unique
ID address.
There are a total of 255 different ID addresses from 001 to 255.
To set up the address for a fixture, use the Menu button in the root menu go to
ID
Press Enter and then using the ↑ or ↓ buttons,to select the ID address.
Press Enter to save the address.
For the ID address to work you must chose a
Personality
that uses the ID. For example STAG
This allows you to access the ID address system on channel 4.
Set the DMX address to 001 for the fixture. So if ID address 123 is chosen then go to channel 4 on the
lighting board and set the level at 123. You will then be controlling only fixture(s) with ID address 123.
ID address 001 is the default and in ID address 001 all fixtures will be under control.